Output power per relay:
- incadescent / halogen 230V
- halogen 12V with transformer
- LED with transformer or compact
- fluorescent with electronic ballast
- parallel compensated fluo lamps
- electric heater (any resistive load)
Expected contact life:
Total output power all channels (mk1):
Total o
utput power
per group (mk2)
:
Maximum
length of
input cable:
Power supply:
Ingress protection:
Operating temperature:
Storage temperature:
Relative humidity:
Dimensions:
Weight:
Standards:
800W
400W
400W
400W
250W/30uF
1400W
20000 (100% load)
100000 (50% load)
40
00W
28
00W
50m
24V
120mA
IP20
0..45°C
-20..75°C
0..95% n/c
106x108x58mm
250g
EN 60730-1
LC-10-IQ light controller
Mounting: 35mm DIN rail 6M
106
10 relay outputs
33
Hardware
Output mode
on
off
on/off mode
button
turns light on and off
on
off
timer mode
button
turns light on, and it
automatically goes off after
the predefined time
6A MCB (miniature circuit breaker) type B is recommended.
mk1 (1x10): When total power of all channels is less then 1400W,
a single 6A MCB is connected to both L terminals. Otherwise each
channel should have a separate 6A MCB.
mk2 (4+6): When total power of each group is less then 1400W, two
6A MCBs are connected to terminals L0 and L1. Otherwise each
channel should have a separate 6A MCB.
Managed socket should always have a separate 6A MCB. Each
output must be connected to a single socket. Socket must have a
noticeably different front plate with the label: "Caution: 1400W max".
Circuit protection
power outage:
<
10min -
come back
>
10min - lights will stay off
lights
Features
nominal output current
managed socket
for devices such as dehumidifier,
...
hi-fi system
,
floor lamp,
portable
fan, electric
mosquito repellent
Caution: 1400W max
Input mode
toggle (on
/
off)
staircase timer
motion sensor
doorbell
door sensor
scene
(
on/off
)
sensor for
ready light
disabled
Input mode define how an input affect the output. Toggle, staircase,
doorbell, motion and door sensor are handled internally. Scene and
ready light are handled by master controller.
LC-10-IQ mk2
L0
+24V
QX0
0V
IX0
QX1
C
QX2
IX1
QX3
C
IX2
L1
IX3
QX4
IX4
QX5
C
IX5
QX6
C
IX6
QX8
QX7
IX7 IX8
QX9
IX9
C
230V
ac
LC-10-IQ mk1
QX0
QX4
IX0
IX4
L
0V
L
+24V
QX1
QX5
C
C
QX2
QX6
QX8
IX1
IX5
QX3
QX7
QX9
IX3
IX7
IX9
C
C
C
IX2
IX6
IX8
230V
ac
Technical specifications
Содержание HIQ Home
Страница 1: ...User Manual v1 3 1 HIQ Home...