![Robot Pumps RW-R-SERIES Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/robot-pumps/rw-r-series/rw-r-series_operation-and-maintenance-manual_1471271026.webp)
Operation &
Maintenance Manual
Pump
RW-R
782-007-GB
HSC
02-W51
Edition 1
27/28
APPENDIX 4; Single phase motor
PUMP CABLE CONNECTIONS
P
line (phase)
O
line (neutral)
e
fuse
K
motor protection
C
capacitor
H
main coil
h
starter coil
T
thermostats
(250V-1,6A max.)
earth
MOTOR
WIRING
COLOUR
* 1
blue / white
* 2
red / white
* 3
red / white (thick)
* 4+5
red
PUMP CABLE
BR
=brown
BL
=blue
B
=black
G/Y
=green/yellow
CONTROL PANEL
P, O
=line
C
=capacitor
T
=thermostats
Wa
=water detector
(if fitted)
=earth
EXAMPLE OF A SINGLE PHASE CONNECTION DIAGRAM
In some situations where a longer pump cable is used an extra 10 mm
2
/AWG 8 earth cable is fitted to the
motorhousing to fulfill the demands of the Low Voltage Directive. Always connect this cable also to the earth
connection!
motorwiring
www.robotpompen-onderdelen.nl