![Robot Pumps RW-R-SERIES Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/robot-pumps/rw-r-series/rw-r-series_operation-and-maintenance-manual_1471271014.webp)
Operation &
Maintenance Manual
Pump
RW-R
782-007-GB
HSC
02-W51
Edition 1
15/28
7.4
Cable entry
Especially when the pump has been in use for a long
time, the compression of the rubber cable
seal might be deminished, which can cause leakage. By
screwing-in the cable entry the seal will be retensioned.
Unscrew the 2 hexagon socket screws (1). See fig. 7.1.
Remove the cable clamp (2).
Turn the hexagon head of the entry (1) clockwise, using
the right tool, so far that it is possible to replace the
cable clamp again.
Screw-in the 2 hexagon socket screws (1).
It is possible that your pump is fitted
with 1 or 2 cables.
Fig. 7.1
www.robotpompen-onderdelen.nl
T +31(0)294-457712