COTTON CANDY MACHINE ACB-09E
REVISED 28-Sep-17
10
spinning head volume.
Get ready in advance special sticks for cotton candy winding. The sticks
can be made of wood, paper or plastic. The longer the stick the bigger
servings of cotton you can make. For vertical flow machine perfect length of
stick would be 50-60 cm.
For better adhesion, moisten sticks with water before use.
Set the switch (11) in ON position, spinning head starts to rotate. Before
turning the heat on, check airflow from the impeller. To do this, place your
palm 10 cm above the spinning head.
ATTENTION! VIBRATION ON MOMENT OF MOTOR STARTING OR
STOPPING IS A NORMAL THING AND IS NOT A BUG!
If airflow isn’t intensive enough, turn off the machine and adjust silicone
ring on the stator (see below
Air flow adjustment
section).
Once air flow is adjusted, turn on the heating using the switch (12), and
immediately turn adjustment knob (13) to set voltmeter
1
(14) at 150-160V.
It will take about 1 minute to warm up the head. Once head is warmed up,
cotton candy starts to fly out of the head.
One should winds cotton candy on a stick 20-40 cm above the spinning
head, rapidly turning the stick with fingers (see the figure below).
Cotton candy will fly out upwards, as a vertical column, so-
called ‘sleeve’.
1
At the first start on a site, power level must be adjusted accordingly to the real conditions. If
cotton candy comes out too slow, an operator should increase the voltage; if it comes out
too fast, then the voltage should be decreased. For future operation there is no need to
adjust, leave it on the suitable value. Once operator is found a suitable voltage level, it
must be remembered or marked on the voltmeter (14). If you change the site, you must
make adjustment again, depending on new conditions.