background image

 
Switch 1,

 ON 

in this mode the unit will function 

as a repeater station. (Indicated by slow flashing 
LED in normal operation) 
 

Switch 2, 3, and 4

 will implement the 

following delay between receiving and 
transmitting a signal; this is important when 
installing multiple repeaters and will avoid 
possible signal “clashing”. 
 
Delay:  

Switch 1: 

Switch 2: 

Switch 3: 

2.4 SEC  

OFF 

OFF 

OFF 

2.8 SEC 

OFF 

OFF 

ON 

2.8 SEC 

OFF 

ON  

OFF 

4    SEC 

OFF 

ON 

ON 

4.8 SEC 

ON 

OFF 

OFF 

5    SEC 

ON 

ON 

OFF 

6.5 SEC 

ON 

ON 

ON 

 

Wiring:

  Connect the Universal Transmitter to a 

12 V power supply.  Wire the 12V, ground, and 
RXD of the Universal transmitter to a receiver. 

SELECTING REPEATER STATION 

Содержание Universal TX

Страница 1: ...User Manual Universal Transmitter TX And Repeater A Division of TRAP INTERNATIONAL C C ...

Страница 2: ...ls The input zone sends an intruder signal as soon as the input state is changed N C to N O or visa versa and will stop sending the supervisory auto test signal if it remains in the altered state hereby monitoring functionality of the devices wired to it Alternatively a Universal TX can be wired to a receiver and configured to be a repeater station for increased radio distance 400 meter radio rang...

Страница 3: ...al this is important when installing multiple repeaters and will avoid possible signal clashing Delay Switch 1 Switch 2 Switch 3 2 4 SEC OFF OFF OFF 2 8 SEC OFF OFF ON 2 8 SEC OFF ON OFF 4 SEC OFF ON ON 4 8 SEC ON OFF OFF 5 SEC ON ON OFF 6 5 SEC ON ON ON Wiring Connect the Universal Transmitter to a 12 V power supply Wire the 12V ground and RXD of the Universal transmitter to a receiver SELECTING ...

Страница 4: ...will be sent This will allow you to program the Roboguard into your appropriate decoder panel Tamper signals are required to programme Roboguards into decoder panels and will be sent when the relevant zone input is triggered NB When programming is complete turn Switch 2 off When mimicking Remote TX signals Switch 3 ON keep switch 2 off and program the input zones into remote TX zones of the decode...

Страница 5: ...zones that are N O disconnected Turn Switch 4 on and off to programme The programme LED will flash the number of times on the chart below to confirm the desired zone input configuration Zone 1 2 3 4 1 flash N C N C N C N C 2 N O N C N C N C 3 N C N O N C N C 4 N O N O N C N C 5 N C N C N O N C 6 N O N C N O N C 7 N C N O N O N C 8 N O N O N O N C 9 N C N C N C N O 10 N O N C N C N O 11 N C N O N C...

Страница 6: ... can now be tested by triggering the individual devices to confirming if they are working on the decoder panel The LED is used to indicate different settings and events In normal operation the LED will flash slowly for a repeater and fast when configured as a Universal TX When the Universal transmits the LED will flash faster for the duration of the transmition For a repeater the LED will go solid...

Страница 7: ... on disconnection LED fast burst of flashing and the N O zones will do nothing as they are still N O By turning switch 4 on and off the Universal transmitter will learn the current state of the zones hence if a device is in the alternate i e N C switch being in an N O position state the wrong configurations re programmed as described on page 5 Trouble Shooting Notes ...

Страница 8: ...s Dimensions 104 X 64 X 27 Weight 100 g Current consumption 5 2 mA Required Receiver U H F 433MHz Colour White Trap International CC PO BOX 38113 Point 4069 Durban South Africa sales roboguard co za www roboguard co za ...

Отзывы: