1.
The appliance name and serial number are on the
d
ata badge
wh
ich
i
s
l
ocated on the
l
ef
t
hand
s
ide of the fire base panel
.
Remove
the fender and ash-pan cover for access to read the data badge
.
(See
Fi
g
s 1a
n
d
2).
3
.
This fire must be installed and serviced regularly in accordance wi
th t
h
e
G
as S
a
f
e
ty
(
In
s
t
a
llation and Use) Regulations and the rules
in force by a competent
person e
.
g
.
British Gas or CORGI mem
b
e
r
. W
h
ere s
ol
id
fu
e
l h
a
s been used the chimney must be swept
before installation
.
This fire must be installed in accordance with th
e
i
n
s
ta
l
l
at
i
o
n
i
ns
tru
ct
i
o
n
s
.
4
.
It is recommended
that at least once a year the appliance shoul
d be re
m
oved to check
t
he ca
t
chment space and the chimney for
debris
.
The f
i
re should be checked annually to ensu
r
e continue
d
cleara
n
ce of combustio
n
pro
d
ucts and that there is no excessive
build up of soot
.
5.
WARNING
:
This fire has a naked flame
.
Also certain parts
,
espe
cially the canopy
,
w
i
ll be h
o
t w
h
e
n in use
.
A fireguard conforming to
B
.
S
.
6539 (Fireguards for use with solid fuel appliances) should
b
e use
d
for
t
he protec
ti
o
n
of children
,
the elderly or the infirm
.
Such
a guard is also recommended
for pet animals
.
6.
After the fire is installed you may wish to fix a shelf above
.
Th
i
s is
quite
acce
ptab
l
e
pro
vi
de
d that the underside of the shelf is at least
237mm above the fire and does not project more than 150mm f
or
wa
rd
.
F
or a
d
ee
per s
h
e
lf allo
w
13mm increase in shelf height for
every 25mm increase
i
n shelf depth
.
8
.
When the fire is first used it may give off
s
ome slight smoke and
sme
ll
b
u
t these will soon c
lear
a
fter a few hours of use at the HIGH
setting.
10
.
IMPORTANT:
When
considering
fitting
any
heat
i
ng
appliance
or wallpapering
a room in which one i
s
fitted, if
blown vinyl or other heat sensitive wallpapers
are used in
the
vicinity of the heat source, then they may bec
o
me heat
damaged or discoloured especially just above the fir
e
.
11
.
It is important for safe operation
and to maintain e
f
ficien
c
y
that the fire is not operated with damaged or bro
k
en
c
oals
.
IMPORTANT
NOTE:
Under no circumstances
should ext
r
a
coals be used together with the existing coals.
ONLY THE CORRECT COALS SHOULD BE USED.
12
.
If purpose built ventilation
is provided for the fire, it shou
l
d
be checked
periodically
to ensure
that
it is free from
obstruction.
On pre-cast flue installations
the walls must be dry lined
over
the
route
of the
flue.
Dry
lining
is the
use
of
plasterboard
w
i
th an air space between
the wa
l
l and the
plaster board. Installation
must not be made into pre-cast
flues that have plaster applied directly to the surfa
c
e of the
wall i
.
e
.
wet lined
,
because
experience
has shown that in
some wet lined installations
the lack of heat in
s
ulation
provided by plaster can cause the plaster to shrink or crack
and other decoration
such as wallpaper
to discolour
or
detatch from the wall
.
This product uses fuel effect pieces containin
g
R
e
fracto
r
y
Ceramic Fibre (RC F)
,
which are man-made vitreou
s s
ilica
t
e
fibres. Excessive
exposure
to these materials
may cause
temporary
irritation
to eyes
skin and
respiratory
tract,
consequently,
it makes sense to take care when hand
l
ing
these articles to ensure that the release of dust is
ke
pt to a
minimum
.
57568
Содержание 32-170-23 A
Страница 9: ... NOTEPAD 57568 ...