Pre-installation 

Thank you for purchasing a quality Robinhood 

rangehood.  Robinhood has a high standard of 

quality control and every rangehood is tested 

and approved before it leaves the factory

 

 

 

 

Important: 

 

Please read the entire instructions before installing the rangehood, always switch power off prior to installation. 

All electrical work must be done by a registered electrician in accordance with local and national electrical codes 

as applicable. For your safety, this product must be earthed. 

 

The power socket must be accessible and enable the end user to isolate the rangehood from the power for the 

purpose of internal cleaning or maintenance. 

 

A power outlet should be within 1500mm of the power cord exit from the rangehood. 

 

The canopy hood is not intended for use by persons (including children) with reduced physical, sensory or metal 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety 

 

Children should be supervised to ensure that they do not play with the appliance. 

 

There shall be adequate ventilation of the room when the rangehood is used at the same time as appliances 

burning gas or other fuels. 

 

There is a fire risk if cleaning is not carried out in accordance with the instructions. You must read the details 

concerning the method and frequency of cleaning. 

 

Do not flambé under the rangehood. 

 

Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances 

burning gas or other fuels. 

 

The minimum distance between the hob surface and the lowest part of the rangehood is 600mm. This distance 

shall be at least 650mm, if the rangehood is installed over a gas hob.  If the instructions for the gas hob specify 

a greater distance, this has to be taken into account. 

 

Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air is 

fulfilled. If re-circulating, ensure that the side outlet grilles on the upper chimney are not obstructed.  Even a 

partial obstruction will restrict the efficiency of the rangehood. 

 

Stainless steel is very easily damaged during installation if abraded or knocked by tools.  Protect the rangehood 

with the cardboard box or plastic bag during installation. 

 

Check the contents of the packaging, check all electrical functions of the canopy before installation.  

Canopy is heavy. Please ensure adequate care when installing to prevent personal injury. 

 

CAUTION: Accessible parts may become hot when used with cooking appliances 

 

 

 

Содержание RPB3CL6SS

Страница 1: ...Description ROBINHOOD POWERPACK RANGEHOOD Model Numbers RPB3CL6SS WH RPB3CL9SS WH Product may vary slightly from the picture Issue 3 ...

Страница 2: ...e same time as appliances burning gas or other fuels There is a fire risk if cleaning is not carried out in accordance with the instructions You must read the details concerning the method and frequency of cleaning Do not flambé under the rangehood Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances burning gas or other fuels The minimum dist...

Страница 3: ...et from the motor requires 150mm round ducting which requires 170mm diameter hole in the ceiling if ducting through the ceiling Minimum height from the hob top surface to the underside face of the rangehood 600mm electric hob 650mm gas hob Notes If the instructions for the gas hob specify a greater distance this has to be taken into account Any installation above 750mm will compromise performance ...

Страница 4: ...od The guide below recommends the ducting components to use for all common ducting configurations through the top of the home for the roof and soffit and through the rear of the home 150mm round ducting should be used in conjunction with this model rangehood Extra lengths and or bends may be required depending on the length required and whether there is any structural material in the way e g rafte...

Страница 5: ...e rangehood the lower edge of the unit must be a minimum of 600mm 650mm for gas cooker above the cooking range The recommended position for the hood is 650mm above the hotplates Pictured Minimum height from the hob surface to the underside face of the rangehood is 600mm for electric hob 650mm for gas hob Notes If the instructions for the gas hob specify a greater distance this has to be taken into...

Страница 6: ...nit then are accessible Lift the rangehood and fit through the opening of the cupboard Secure unit using long screws supplied Refit face plate then refit the LED bulbs Model may vary slightly from images pictured Recirculation mode 1 This unit can be installed to operate in recirculation mode where ducting is not a chosen desired or practical option Ducting may still be required to vent air from a...

Страница 7: ...hood and allow the bulb to cool 2 Remove the bulb by turning it by hand in an anti clockwise direction 3 Care must be taken to avoid the bulb falling onto the hob top 4 Replace the bulb by inserting it into the socket and hand turning in a clockwise direction Optional accessories For other accessories parts and service please contact your local supplier Refer to the Warranty Certificate CHARCOAL F...

Страница 8: ... into an existing flue which is used for exhausting fumes from appliances burning gas or other fuels The minimum distance between the hob surface and the lowest part of the rangehood is 600mm This distance shall be at least 650mm if the rangehood is installed over a gas hob If the instructions for the gas hob specify a greater distance this has to be taken into account Attention should be given to...

Страница 9: ...sing the product to acidic or corrosive materials or chemicals such as dyes solvents denture cleaner or acetone Using inappropriate household cleaning products such as abrasive cream or powder cleansers furniture polish bleach mentholated spirits drain cleaners sugar soap metal pads and strongly alkaline or acidic cleaners Heat damage including from washing the product at high temperatures Impact ...

Страница 10: ...eet Kingsgrove NSW 2208 within 7 days of any alleged defect or failure of the product first becoming apparent you are responsible for the expense of making a claim under this warranty This warranty is given by Shriro Australia Pty Ltd ABN 28 002 386 129 Telephone 1800 648 556 Facsimile 1800 628 577 Email enquiries robinhood com au www robinhood com au Attention Customer Services Manager Warranty e...

Отзывы: