Safety Functions and Error Display
ERROR CODE
ERROR DESCRIPTION
RESOLUTION
E0
No Pot (or pot unsuitable) Add pot, use correct type of pot or change to
correct size.
E1
Input voltage too low
Voltage below 160V. Contact power supply
company.
E2
Input voltage too high
Voltage above 270V. Contact power supply
company.
E3
IGBT sensor overheated
Sensor has reached 105°C. Appliance shut down
until temperature drops to 50-70°C
E4
Temperature sensor error Sensor shorted or open circuit. Contact the
authorised service centre.
E5
IGBT sensor error
Sensor shorted or open circuit. Contact the
authorised service centre.
E6
Overheat
Appliance should restart once cooled down.
E7
Sensor failure
Contact the authorised service centre.
E9
Communication error
Loose wire or poor connection. Contact the
authorised service centre.
Eb
Line fault
Connection to inductive coils not correct. Contact
the authorised service centre.
H
High temperature on glass Glass hot, induction fan runs. Indicator turns off
when cooled (appliance runs as normal).