complete, an alarm will sound and the next preset time will automatically start counting
down. If no time is entered (i.e. all zeros) the timer will automatically advance to the
next preset time and become active.
To de-activate LOOP sequence while in TIMER mode, press (B) to stop countdown and
then press (A) to reset to the preset time.
During SINGLE function, Loop symbol (
4
) does not appear. The current preset time
will countdown and manual sequencing of preset times is required by pressing (A).
Setting the Countdown Time(s):
After selecting timer function and single/loop setting,
press (C). Countdown hours begin to flash in the lower row. Advance hours by pressing
(A)
or decrease hours by pressing (B). Press (C) again and minutes begin to flash.
Advance minutes by pressing (A) or decrease by pressing (B). Repeat this procedure for
seconds and tenths. You may exit the setting function at any time by pressing (D).
You may input countdown times from 0.5 seconds to 16 hours. You may input
countdown times whether the TIMER mode is active (counting down) or stopped (reset).
Using the Countdown Timer(s):
Input the preset times and TIMER function (CR, CS,
CC), select LOOP or SINGLE option and start countdown by pressing (B). Time will
count down in 1/10 second increments in top row.
You may stop the countdown time by pressing (B) again. Then press (B) again to restart
countdown. Press (A) to reset to next countdown time or press (D) to reload current
preset time.
Please note the following:
TIMER function operation is based on whether LOOP or
SINGLE option is selected.
With the LOOP SEQUENCE active, (
4
) symbol appears.
• COUNTDOWN STOP (CS) will auto-sequence through all preset times for one cycle
(i.e. 1 through 5 only).
• COUNTDOWN REPEAT (CR) will auto-sequence through all preset times
continuously until manually de-activated (Press (B)).
• COUNTDOWN CHRONO (CC) will auto-sequence through all preset times for one
cycle and activate chronograph instantly upon completion of last preset time.
• With SINGLE option active (
4
) symbol does not appear.
COUNTDOWN STOP (CS): Press (B) to start countdown. Alarm will sound at
completion of preset time. Reset to current time by pressing (D) or sequence to next
preset time by pressing (A).
COUNTDOWN REPEAT (CR): Press (B) to start. Alarm will sound at completion and
timer will automatically reload and repeat countdown instantly.