![Robe Stage Faze 1500AT Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/robe/stage-faze-1500at/stage-faze-1500at_user-manual_1468985009.webp)
8
9
Auto start
If the timer is in operation and you disconnect the machine from the mains cable, the StageFaze 1500 AT
will re-start in the Timer-Mode as soon
as it‘s reconnected to the mains. To stop this press the Mode-button for more than 2 seconds or by switching to „ESC“ in the Timer-Mode and then
press the Enter-button.
7. Cleaning,care and maintenance
Remove the filter, which protects the fan against dust and dirt, from time to time and clean it.
– After several hours of operation, some droplets of condensation will have formed at the nozzle. That is normal and not a malfunction.
Please note: Remove fluid droplets at the nozzle only when the machine has completely cooled off. During operation the nozzle gets very hot!
– Do not let the StageFaze 1500 AT
run without any fluid as the pump will run dry.
– Check the state of the fluid filter [18] from time to time and clean or replace it when necessary.
– PLEASE NOTE: The vaporizer of the machine does not have to be cleaned! Cleaners, available on the market, can damage the vaporizer!
8. Troubleshooting
Trouble: The pump runs, but little or no Faze is produced.
Cause: The pump sucks no or too little fluid.
- Check whether the tank is empty
- Check whether the brass collar is properly connected with the brass coupling
- Check whether the fluid filter in the tank is clogged
- Check whether the fluid tube is twisted or defective
Trouble: The yellow LED at the machine does not light up (only when running via DMX)
Cause: Connection from the machine to the desk is faulty.
- Check whether the plug is plugged in correctly
- Check whether the cable is defective
- Check whether the DMX start address is adjusted correctly
Trouble: During operation the StageFaze 1500 AT
fails to work for a long time
Cause: The overtemperature protection device is activated.
- Check whether the fan is clogged
Trouble: E-4 appears on the LED display:
Cause: The machine is getting too hot. The heating switches off and the machine cools down.
Solution: Disconnect the machine from the mains supply for a moment and then re-connect it.
Trouble: E-8 appears on the LED display:
Solution: The vaporizer is clogged.
Cause: Please send the machine to your local dealer.
Trouble: E-1 appears on the LED display:
Solution: Please send the machine to your local dealer.
9. Specifications
Power requirement:
1500 Watt
Voltage:
230 V/ 50 Hz or
Fuse:
8A at 230 V
Warm up time:
approx. 60 Seconds
Fluid tank capacity:
2 liters
Integrated Fan:
> 6000 l/min.
Faze density:
variable
Control:
DMX 512
Weight (without liquid)
:12 kg
Max. tilt inclination
:+30°/-30°
Dimensions
:
Accessories
: Omega holder (No.99010420).............1pcs
Specifications are subject to change without notice.
Содержание Stage Faze 1500AT
Страница 1: ...Version 1 1 ...