Robe Stage Faze 1500AT Скачать руководство пользователя страница 3

2

3

1.Introduction

Thank you for choosing an ROBE StageFaze 1500 AT.  You now own a rugged and powerful state-of-the-art machine.  Prior to use, 
we suggest that you carefully read all of the instructions.  By following the suggestions found in this user manual, you can look forward 
to the reliable and satisfactory performance of your ROBE Stage Faze 1500 AT machine for years to come.

Please follow these operation, safety and maintenance instructions to ensure a long and safe life for your fog machine.

2.Cautions

Risk of electric shock.  Disconnect the appliance from the electric supply before 

removing the cover. 

 
Note: there are no user serviceable parts inside.

 

Danger of Electric Shock

 

Keep this device dry.

 

For inside use only. Not designed for outside use. 

 

 

Prior to use take care to determine that the unit is installed at the rated voltage.

 

Always unplug your ROBE Faze machine before filling its tank.

 

Keep fog machine upright.

 

Unplug the machine when not in use.

 

This machine is not water - or splash-proof.  If moisture, water, or fog liquid gets inside the housing, immediately unplug  

 

the unit and contact a service technician or your ROBE distributor before using it again.

 

No user serviceable parts inside.  Refer to your ROBE distributor or other qualified service personnel.

 

Danger of Burns

 

For adult use only. Never leave the unit running unattended.  

 

Never aim at persons directly and keep a minimum distance of 3 m to the nozzle.

 

Faze machine output area is very hot.

  Avoid coming within 60 cm of the output nozzle during operation.

 

Keep a minimum distance of 60 cm to all flammable, combustible objects and objects sensitive to heat.

 

Locate the Faze machine in a well-ventilated area.  Never cover the unit's vents.  

 

Never aim the output nozzle at open flames.

 

If the supply cord is damaged, it must be replaced by manufacturer or its service agent or similarly qualified personnel in  

 

order to avoid a hazard.

 

Always allow your StageFaze 1500 AT to cool down before attempting to clean or service it.

  

Danger of Explosion

 

Never add flammable liquids of any kind (oil, gas, perfume) to the Faze liquid.

 

Use only original liquid recommended by ROBE distributor.

 

Spilled fluid or splashed fluid droplets can cause slip hazard.

 

Always make sure there is sufficient liquid in the Faze liquid tank. Operating this unit without liquid will cause damage

 

 to the pump as well as over-heating of the heater.

 

If your ROBE Faze machine fails to work properly, discontinue use immediately. Drain all fog liquid from the tank, pack the 

unit securely (preferably in the original packing material), and return it to your ROBE distributor for service.
Always drain tank before mailing or transporting this unit.
Never drink fog liquid.  If it is ingested, call a doctor immediately. If fog liquid comes in contact with skin or eyes, rinse thoroughly with 
water.

Pay attention to all warning labels and instructions printed on the exterior of 

 StageFaze 1500 AT

 

People with health problems or problems of therespiratory tract or with an inclinati-

on for allergies should avoid any contact with artificially-made fog.

Содержание Stage Faze 1500AT

Страница 1: ...Version 1 1 ...

Страница 2: ...e device 4 5 Fluid 5 5 1 General notes 5 5 2 Filling the fluid tank 5 6 Operatting the StageFaze 1500 AT 5 6 1 Selecting a location 5 6 2 Putting into operation 6 6 2 Switching the StageFaze 1500 AT off 6 7 Cleaning care and maintenance 9 8 Troubleshooting 9 9 Specifications 9 StageFaze 1500 AT ...

Страница 3: ...hine output area is very hot Avoid coming within 60 cm of the output nozzle during operation Keep a minimum distance of 60 cm to all flammable combustible objects and objects sensitive to heat Locate the Faze machine in a well ventilated area Never cover the unit s vents Never aim the output nozzle at open flames If the supply cord is damaged it must be replaced by manufacturer or its service agen...

Страница 4: ...s no evident damage caused by transportation In the event that the unit s housing or cable is damaged do not plug it in and do not attempt to use it until after contacting your ROBE distributor for assistance 4 Description of the device Front view Rear view 1 Nozzle 8 Tilt lock 2 Control panel 9 Power cord 3 Handle 10 Powe switch 4 Fluid tank 11 Fuse holder 5 Fluid tube 12 DMX IN OUT 3 pin XLR 6 F...

Страница 5: ...re between 10 C and 40 C and the relative humidity below 80 This model includes a mounting bracket designed for overhead installation it may be installed at floor level or suspended overhead If the unit is to be mounted using the bracket it is important that the fog does not shoot directly at any one s face Overhead installation 1 Bolt the clamp C to the omega holder D 2 Fix the omega holder on th...

Страница 6: ... cooled down This will ensure that no fluid remains in the vaporizer to come out as droplets when the device is switched on next time 6 3 Control Choices Fig 1 Adjusting the pump output Fig 2 Adjusting the fan output Fig 3 Adjusting the DMX start address Fig 4 Changing to the Profile Mode Fig 5 Switching the device Off You may control the StageFaze 1500 AT externally through the 3 pin or 5 pin XLR...

Страница 7: ... 1 99 by pressing the Up or Down button 3 Press the Mode button again until an F and two figures appear on the display see Fig 2 4 With the Up or Down button the fan data can now be adjusted 5 Press the Enter button once to start the machine The green Active LED will be lit 6 6 Faze Density Control System HDCS Fig 6 Adjusting the Pause Pre Runtime Fig 7 Adjusting the pump Fig 8 Start the profile F...

Страница 8: ...it the Timer Mode With the internal timer the Faze time and wait time can be adjusted in minutes 0 1 99 the pump and fan output can be adjusted in per cent 0 99 To start the Timer Mode press and hold the Mode button for more than 2 seconds The red Timer Profile LED will blink as soon as the machine has switched to the Timer Mode As long as the timer is in operation the red Timer Profile LED blinks...

Страница 9: ...s properly connected with the brass coupling Check whether the fluid filter in the tank is clogged Check whether the fluid tube is twisted or defective Trouble The yellow LED at the machine does not light up only when running via DMX Cause Connection from the machine to the desk is faulty Check whether the plug is plugged in correctly Check whether the cable is defective Check whether the DMX star...

Отзывы: