50
at a small toothlike projection (8) on the edge of the rotating gobo wheel.
Important!
When inserting the gobo holder back to the rotating gobo wheel, one of the adjacent gobo holder
has to be oriented according to the same rule, it means that its position point (7) has to aimed at
the toothlike
projection (8) on the edge of the rotating gobo wheel.
10. Screw the lamp cover (2) back to the fixture.
11.
Carefully check the gasket for signs of deformities or hardening and if it is correctly placed in the groove of
the head housing before screwing the head cover back on the head.
12. Screw the head cover on the head.
13. Connect the fixture to the mains.
14. Use the menu Service to calibrate replaced gobos (Service -> Calibration -> Calibrate effects -> R. Gobo
Index 1....9 ).
Warning!
Use only gobos intended for the Robin iPointe65.
Do not try to use gobos from the Robin Pointe.
(The Robin iPointe65 generates heat the gobos of the Robin Pointe are not designed for).
Orientation of gobos in the gobo holders