3. Installation
Fixtures must be installed by a Qualified electrician in accordance with
all national and local electrical and construction codes and regulatio
n.
3.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The iParfect 150 is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC
power source from 100-240 Volts.
Install a cord cap on the power cable to allow connection to power outlet, install a grounding-type (earthed)
plug with suitable IP rating , following the plug manufacturer’s instructions.
If you have any doubts about proper installation, consult a qualified electrician.
Core (EU)
Core (US)
Connection Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green Green
Earth
This device falls under class one and must be earthed (grounded)!
The max. number of connected fixtures in power chain depends on AC mains power voltage:
CE:
ETL:
15 fixtures at power supply= 230V
9 fixtures at power supply= 230V
13 fixtures at power supply= 208V
8 fixtures at power supply= 208V
7 fixtures at power supply= 120V
4 fixtures at power supply= 120V
Actual number of fixtures may differ from values stated above as you have to take into account the length of
supply cables, circuit breaker etc. at projecting of the fixtures installation Do not overload the supply line and
connecting leads.
Wiring and connection work must be carried out by qualified staff!
.