28
Module M
- a Pan/Tilt processor
Module L 1
- a LEDs control processor 1
Module L 2
- a LEDs control processor 2
Module O
- a Focus/Zoom/Light frost control processor
Module F-A
-a Framming shutters control processor
Module F-B
- a Framming shutters/Iris control processor
Module G 1
- a Rot. gobo wheel control processor
Module G 2
- a Rot. gobo wheel control processor
Module P
- a Prisms/Medium frost control processor
Module C1
- a Colour wheel 1 control processor
Module C2
- a Colour wheel 2 control processor
Product IDs -
The menu is used to read the MAC Address ,RDM UID and RDM Label.
LED Module Info
- Use this menu to read LEDs module information.
First Module Assembly
- Use the item to read initial information about the LEDs module installed in
the fixture. The fixture has to be connected to mains to read the values in the menu items.
Serial Number/ Device UID
- a serial number of the LEDs module/RDM UID of the fixture.
Installation Date/Time
- a date/time of the first installation of the LEDs module to a
some iForte device.
Intensity
- an original intensity of the LEDs module in percentages (100%).
LEDs On Time Total/Adaptive
- Total: a total time of the LEDs module operation during which
the dimmer intensity was > 0%.
Adaptive: a relative time of the LEDs module operation during which the dimmer intensity
was > 0% (e.g. if dimmer = 50% for one hour, the adaptive time is 0.5 hour, if dimmer = 100%
for one hour, the adaptive time is 1 hour).
Actual Module Info
- Use the item to read current information about the LEDs module installed in
the fixture.
Serial Number/ Device UID
- a serial number of the LEDs module/RDM UID of the fixture.
Measurement Date/Time
- a date/time of running the procedure "LEDs Measure" in the tab
Service.
Intensity
- the item shows a light intensity of the LEDs module measured after running
the procedure "LEDs Measure" in the tab Service. The light intensity is displayed in percentages
in relation to the initial intensity of the new LEDs module (initial intensity=100%).
LEDs On Time Total/Adaptive
- Total: a total time of the LEDs module operation during which
the dimmer intensity was > 0%.
Adaptive: a relative time of the LEDs module operation during which the dimmer intensity
was > 0% (e.g. if dimmer = 50% for one hour, the adaptive time is 0.5 hour, if dimmer = 100%
for one hour, the adaptive time is 1 hour).
Assembly History
- Use the item to read a history of the LEDs module installed in the fixture (its serial
number, RDM UID of fixture at which was installed and date/time of installation).
Up to 31 records can be saved in the menu item.
I
ntensity History
- Use the item to read a history of light intensity of the LEDs module installed in the fixture.
Serial Number/ Device UID
- a serial number of the LEDs module/RDM UID of the fixture.
Measurement Date/Time
- a date/time of running the procedure "LEDs Measure" in the tab
Service.
Intensity
- the item shows a light intensity of the LEDs module measured after running
the procedure "LEDs Measure" in the tab Service. The light intensity is displayed in percentages
in relation to the initial intensity of the new LEDs module (initial intensity=100%) .
Up to 31 records can be saved in the menu item.
LED Modules History
- Use the item to read a history of the LEDs modules installed in the fixture (their serial
numbers and date/time of installation).
Up to 31 records can be saved in the menu item.
View Logs
- Use this menu to read fixture´s data which have been recorded during fixture operation. This
collected data allows easier troubleshooting.