for one hour, the adaptive time is 1 hour).
Air Filters
- Regular cleaning of the air filters is very important for the fixture´s life and performance.
Bild-up of dust, dirt and fog fluid residues reduces the fixture´s light output and cooling ability.
The two items of this menu help you to keep cleaning period of the air filters.
Alert period
- Cleaning schedule for the fixture depends on the operating environment.
It is therefore impossible to specify accurate cleaning interval. This item allows
you to change the cleaning interval of the air filters. This "alert" value is 300 hours and it
is set as default. Inspect the fixture within its 300 hours of operation to see whether cleaning
is necessary. If cleaning is required, clean all air filters and change the value in this menu
on acceptable level. Min. level of alert period is 10 hours, max. is 300 hours.
Elapsed Time
- The item allows you to read the time which remains to cleaning air filters.
The time period is set in the menu mentioned above.
Expired time period is signalled by a negative mark (-) at the time value and a warning icon
on the display.
Clean the filters and reset this menu item (by touching the text box next to the item
"Elapsed Time").
Fixture Temperatures
- The menu is used to view temperatures of the fixture´s inside.
LEDs temperature
- The menu shows temperature on the LED PCB in the light source
Current
- A current temperature of the LED PCB.
Maximum NonRes.
- A maximum temperature of the LED PCB since the fixture has been
fabricated.
Maximum Res.
- A maximum temperature of the LED PCBs since the counter
was last reset.
In order to reset some counter to 0, touch desired text box under item "Max.Res."
Driver Temperature
- The menu shows temperature on the LEDs control PCB in the fixture head.
Current
- A current temperature on the LEDs control PCB.
Maximum NonRes.
- A maximum temperature on the LEDs control PCB since
the fixture has been fabricated.
Maximum Res.
- A maximum temperature on the LEDs control PCB since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res.
Ambient Temperature
- The menu shows temperature in the fixture base .
Current
- A current temperature in the fixture base.
Maximum NonRes.
- A maximum temperature in the fixture base since
the fixture has been fabricated.
Maximum Res.
- A maximum temperature in the fixture base since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Base Temperature
- The menu shows temperature on the display PCB in the fixture base.
Current
- A current temperature on the display PCB.
Maximum NonRes.
- A maximum temperature on the display PCB since the fixture has
been
fabricated.
Maximum Res.
- A maximum temperature on the display PCB since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
DMX Values -
The menu items allows you to read DMX values of each channel received by the fixture.
Wireless State -
The menu serves for reading of the wireless operation status.
Unlink Wireless Adaptor
- The item serves for unlinking the fixture from a DMX transmitter.
If the wireless module is not installed in the fixture, message" Wireless Module Not Installed" will appear.
Power Channel State
- Select this item to see current setting of the functions, which can be set by menu items
in "Personality" as well as by DMX command at channel "Power/Special functions".
Colour Functions State
- Select this item to see current setting of the colour functions, which can be set by
menu items in "Personality" as well as by DMX command at channel "Colour functions".
Software Version
- Select this item to read the software version of the fixture processors: