   Pin

Function

1

Ground

2

Data -

3

Data +

 

 

 

 

 

   6. DMX control operation      

ROBE HAZE 500 FT PRO has on-board DMX control and the addressing is via the LCD control panel. The 

HAZE 500 FT PRO uses 1 channel to control on/off operation. The channel has a value range from 0 to 255. 

The on/off function can also be programmed with a DMX controller or DMX control software used by lighting 

and effects operator.

DMX protocol:

Channel

DMX value

Function

Type of control

1

    0-250

Unit Off

step

251-255

Unit On

step

Note: Once DMX cable is connected to the unit, then the LCD control panel cannot be used.

7. Hazer Liquid

Never mix oil-based and water-based hazer liquids. Before switching the kind of hazer liquid in use, completely 

drain the hazer´s tank to avoid mixing.

8. Technical specifications

Power : 

 

 

220/240V AC, 50-60 Hz ;  ( or 100 /120 V AC, 50-60 Hz optionally)

Power consuption: 

 

400 W

Tank capacity:  

 

2.5 Liter

Output: 

  

3.000 cu.ft/Min. (105m

3

/min.)

Liquid used:

 

  Premium 

Haze

Fluid cons. rate: 

 

20Hrs./Liter

DMX connection:

 

 

5-pin XLR male/female

Dimensions (LxWxH) mm): 

510

 x 375 x 350 mm 

Weight (empty tank):   

31.5 kg

Version:1.3

February 13, 2018

Specifications are subject to change without specification

Содержание HAZE 500 FT PRO

Страница 1: ...USER MANUAL Version 1 3 HAZE 500 FT PRO ROBE Lighting s r o Czech Republic www robe cz ...

Страница 2: ......

Страница 3: ...ntents 1 Introduction 4 2 Cautions 4 3 Unpacking Inspection 5 4 Operation and filling Haze liquid 5 5 Control panel operation 6 6 DMX control operation 8 7 Hazer Liquid 8 8 Technical specifications 8 HAZE 500 FT PRO ...

Страница 4: ...his product is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances Danger of Burn No user serviceable and modifiable parts inside Do not disassemble the housing and do any modification otherwise damage of the device or danger of burn may be c...

Страница 5: ... 6 Set the power switch to ON on the control panel of the machine Make sure to that the red indicator light is on 7 There is an intake hole in the back of the flight case There are a metal net and a filter attached on the intake which can avoid the unit from clogging problem Please inspect and clean the metal net and filter periodically Caution 1 Always monitor and make sure there is sufficient ha...

Страница 6: ... of these operating modes is activated the haze machine will always emit haze when the button MANUAL is pressed Timer operation In the timer mode the haze machine will automatically emit haze The time intervals duration and haze volume depend on the corresponding menu settings Press the button TIMER to activate the timer mode The display indicates the set time interval The unit counts down to 0 se...

Страница 7: ...thermostat has been set off to shut down the hazer If you experience this problem please check two points as described below 1 Check if the mesh filter outside the ventilation fan is clean and without debris If the mesh is covered by dust or obstruction such as paper plastic bag etc the machine is put into a very poor ventilation condition and causes the internal temperature to rise Therefore it i...

Страница 8: ... Unit On step Note Once DMX cable is connected to the unit then the LCD control panel cannot be used 7 Hazer Liquid Never mix oil based and water based hazer liquids Before switching the kind of hazer liquid in use completely drain the hazer s tank to avoid mixing 8 Technical specifications Power 220 240V AC 50 60 Hz or 100 120 V AC 50 60 Hz optionally Power consuption 400 W Tank capacity 2 5 Lite...

Отзывы: