![Robe HAZE 500 FT PRO Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/robe/haze-500-ft-pro/haze-500-ft-pro_user-manual_1468891006.webp)
6
5. Control panel operation
The built-in control panel on the rear of the machine features an LCD panel displaying all operation statuses of
the haze machine. The control panel allows the user to customize functions by adjusting the fogging duration
and interval as well as the DMX address and the door sensor. There are six buttons on the control board. All
current operating parameters are automatically stored in non-volatile memory, allowing the machine to be
powered down without losing function settings. The control buttons are: FUNCTION, Up, Down, TIMER, VOL
-
UME and MANUAL. You can program the necessary menu settings with the control panel when the display
indicates »Ready To Haze«. After switching on, the display shortly indicates » ROBE HAZE 500 FT PRO «
and is ready for haze output. The display indicates »Ready To Haze«.
Continuous operation
When the machine is ready for haze output, short actuation of the button VOLUME activates continuous haze
output. The display indicates »Working«. To stop the haze output, press the button VOLUME once again.
Manual operation
For immediate haze output, keep the button MANUAL pressed. The display indicates »Working«. As soon as
you release the button, the haze output will stop. The manual operation will take priority over the continuous
operation and the timer operation. Even if one of these operating modes is activated, the haze machine will
always emit haze when the button MANUAL is pressed.
Timer operation
In the timer mode, the haze machine will automatically emit haze. The time intervals, duration and haze volume
depend on the corresponding menu settings. Press the button TIMER, to activate the timer mode.
The display indicates the set time interval. The unit counts down to 0 seconds and emits haze. To deactivate
the timer mode, press the button TIMER again.
Menu settings with the button FUNCTION
1. Setting time intervals for timer operation
Press the button FUNCTION until the display indicates »Interval Set«. Use the buttons UP and DOWN to
adjust the intervals between the individual fog outputs in timer mode within the range of 1 and 200 seconds.
2. Setting the output duration for timer operation
Press the button FUNCTION until the display indicates »Duration Set«. Use the buttons UP and DOWN to
adjust the duration of the fog outputs in timer mode within the range of 1 and 200 seconds.
3. Setting the DMX512 address
Press the FUNCTION until the display indicates »DMX 512«. Use the buttons UP and DOWN, to set the
machine to the same address as on your DMX controller. Please refer to chapter DMX512 settings for more
information on DMX operation.
4. Switching the door sensor on and off
Press the button FUNCTION until the display indicates »DOOR ON SENSOR«. Press the button MANUAL
to deactivate the door sensor (indication » DOOR OFF SENSOR «) and the button VOLUME to reactivate it.
Please see *Note 2.