6
7
5.1. Control Module Operation
DMX Fog Control panel:
DMX Fog Control:
10 meter wired multi-function remote control module with 5-pin XLR connector for ROBE
Faze 1000 FT. Its interface allows the operator to customize fog machine functions by adjusting fogging du-
ration, interval and volume. Its LCD displays current operating parameters, which are automatically stored in
non-volatile memory, allowing the machine to be powered down without losing function settings. Instructions
below:
1. Via the Function key, you can adjust the desired settings. Pressing the Function key will cycle through
different options including Volume, Timer, Fan, Heat & Fan and DMX. The Enter (Volume) Key is used to
select the desired option.
To adjust fog output volume setting, simply go into Volume option. Adjust the volume percentage (within
the range of 1% to nonstop burst) by means of Up / Down keys.
To adjust timer setting, go into Timer option. Cycle through Interval (within the range of 1 to 900 seconds),
Duration (within the range of 1 to 200 seconds), and Volume (within the range of 1% to nonstop burst) by
means of Up / Down keys. Use Enter (Volume) Key to select each option and make changes as desired.
To turn off the heater and fan, go into Heat & Fan option. Use Enter (Volume) Key to confirm the selection.
Use On / Off (Manual) Key to turn it on.
To adjust fan intensity setting, go into Fan option. Adjust the fan intensity (within the range of 20% to 100%)
by means of Up / Down keys.
2. Always press Enter (Volume) key to confirm setting.
3. Press ESC (Timer) key to exit current menu level and move to an upper (previous) level.
4. Press the Timer key to activate the timer function. The display shows the adjusted interval and the device
counts the seconds down to "0". After that, the fog emission is triggered at the volume adjusted under
"Timer "Option. The duration depends on the settings adjusted under "Duration". If you wish to deactivate
the timer function, press the Timer key once more.
5. Press the Volume key for immediate triggering of the fog emission at the volume adjusted under "Volume"
Option. Press the Volume switch once more in order to stop the fog emission.
6. Press the Manual key for immediate triggering of the fog emission at 100 % volume. Let the Manual key
loose in order to stop the fog emission.
7. When in standby mode, press On/Off key to reactive the machine.
DMX protocol:
Channel
Value
Function
1
0 - 255
Fan intensity
Fan intensity from min. to max.
2
0 - 5
6 - 249
250 - 255
Fog volume control
Fog output is off
Volume Control (5%-95%)
Maximum Volume Output (100%)
Содержание Faze 1000 FT
Страница 1: ...USER MANUAL Version 1 0 ROBE Show Lighting s r o Czech Republic www robe cz...
Страница 2: ......
Страница 9: ...9...