5.1. Control Module Operation

DMX Fog Control panel:

DMX Fog Control:

 10 meter wired multi-function remote control module with 5-pin XLR connector for ROBE 

Faze 1000 FT. Its interface allows the operator to customize fog machine functions by adjusting fogging du-

ration, interval and volume. Its LCD displays current operating parameters, which are automatically stored in 

non-volatile memory, allowing the machine to be powered down without losing function settings. Instructions 

below:

1. Via the Function key, you can adjust the desired settings. Pressing the Function key will cycle through 

different options including Volume, Timer, Fan, Heat & Fan and DMX. The Enter (Volume) Key is used to 

select the desired option. 

To adjust fog output volume setting, simply go into Volume option. Adjust the volume percentage (within 

the range of 1% to nonstop burst) by means of Up / Down keys. 

To adjust timer setting, go into Timer option. Cycle through Interval (within the range of 1 to 900 seconds), 

Duration (within the range of 1 to 200 seconds), and Volume (within the range of 1% to nonstop burst) by 

means of Up / Down keys. Use Enter (Volume) Key to select each option and make changes as desired. 

To turn off the heater and fan, go into Heat & Fan option. Use Enter (Volume) Key to confirm the selection. 

Use On / Off (Manual) Key to turn it on.

To adjust fan intensity setting, go into Fan option. Adjust the fan intensity (within the range of 20% to 100%) 

by means of Up / Down keys.

2. Always press Enter (Volume) key to confirm setting.

3. Press ESC (Timer) key to exit current menu level and move to an upper (previous) level.

4. Press the Timer key to activate the timer function. The display shows the adjusted interval and the device 

counts the seconds down to "0". After that, the fog emission is triggered at the volume adjusted under 

"Timer "Option. The duration depends on the settings adjusted under "Duration". If you wish to deactivate 

the timer function, press the Timer key once more.

5. Press the Volume key for immediate triggering of the fog emission at the volume adjusted under "Volume"

Option. Press the Volume switch once more in order to stop the fog emission.

6. Press the Manual key for immediate triggering of the fog emission at 100 % volume. Let the Manual key 

loose in order to stop the fog emission.

7. When in standby mode, press On/Off key to reactive the machine.

DMX protocol:

   

Channel

Value

Function

1

0 - 255

Fan intensity

Fan intensity from min. to max. 

2

0 - 5

6 - 249

250 - 255

Fog volume control

Fog output is off

Volume Control (5%-95%)

Maximum Volume Output (100%)

Содержание Faze 1000 FT

Страница 1: ...USER MANUAL Version 1 0 ROBE Show Lighting s r o Czech Republic www robe cz...

Страница 2: ......

Страница 3: ...ion 4 2 Cautions 4 3 Unpacking Inspection 5 4 Setup 5 5 Operation 5 5 1 Control Module Operation 6 5 Technical specifications 7 6 Performance Notes 7 7 Configuration the pump power for local AC power...

Страница 4: ...e directly at people Fog machine output area is very hot Avoid coming within 60 cm of the output nozzle during operation Locate the fog machine in a well ventilated area Never cover the unit s vents I...

Страница 5: ...ss the appropriate button on the control module for the desired length of time The control unit s display will cycle Warming up and Ready to Fog as the machine re heats to the proper operating tempera...

Страница 6: ...as desired To turn off the heater and fan go into Heat Fan option Use Enter Volume Key to confirm the selection Use On Off Manual Key to turn it on To adjust fan intensity setting go into Fan option...

Страница 7: ...r more 5 Technical specifications Power supply Power consumption 1000 VA Voltage AC 230 V 50 Hz Fuse T5 A 230V Tank capacity 2 5 Liter Output 3 500 Cu ft Min Heat Up time 12 min Liquid cons rate 45 Mi...

Страница 8: ...erature at which it vaporizes However a properly maintained fog machine should provide years of reliable use Clean with a dry cloth only Store dry Cleaning your fog machine regularly will help reduce...

Страница 9: ...9...

Отзывы: