![Robe ClubScan 150CT Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/robe/clubscan-150ct/clubscan-150ct_user-manual_1468937019.webp)
18
19
For time control of the fixtures select item "
tiM
" on the master and all slaves.
For audio control of the fixtures select item "
Au.P.
" on the master and all slaves.
For audio random selection of effects ,select item "
Au.r
" on the master and all slaves
Note: Master-slave operation is only possible among fixtures: ClubScan 150,ClubScan 250,Fusion,
Funky and Trance.
10. Error and information messages
C.Er.
(color-wheel error)
This messsage will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The color-
wheel is not located in the default position after the reset.
G.Er.
(static gobo-wheel error)
This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The static
gobo-wheel is not located in the default position after the reset.
M.Er.
(Master error)
The message informs you that the fixture was addressed as a master and DMX signal is connected to its
input.Disconnect the DMX controller from fixture's input and make a reset.
11.Technical specifications
Power supply:
EU version
-Voltage......................208,230 ,240 V AC, 50/60Hz ~
-Fuse..........................T 2,5 A@ 230V
US version
-Voltage......................100,120,208,230,240 V AC, 50/60Hz ~
-Fuse..........................T 5 A@ 120V
-Power consumption.....220VA
Lamp:
Osram HSD 150/70 ,G12
Optical System:
- High reflecting aluminium-coated parabolic reflector
- Manual focus
- 19° beam angle
Beampath:
Содержание ClubScan 150CT
Страница 1: ...Version 2 3 ...