4
12. Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build
up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER !
Disconnect from the mains before starting any
maintenance work
The front objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing
the light-output very quickly. The cooling-fans should be cleaned monthly.
The interior of the fixture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
Dichroic colour filters, CMY lamellas, gobo and graphic wheels and the internal lenses should be cleaned
monthly.
Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum-cleaner.
Important! Check the air filters periodically and clean before they become
clogged!
Clean two air filters placed in the fixture´s covers and two in the fixture base. Use a vacuum cleaner, compressed
air or you can wash them and put back dry.
After replacing the air filters, reset the elapsed time counter in the menu "Information" (Information--->Air Fil
-
ters---> Elapsed Time).
Replacing the fuse.
Before replacing the fuse, unplug mains lead.
1) Remove the fuse holder on the rear panel of the base with a fitting screwdriver from the housing
(anti-clockwise).
) Remove the old fuse from the fuse holder.
3) Install the new fuse in the fuse holder (only the same type and rating).
4) Replace the fuseholder in the housing and fix it.
13. ChangeLog
This section summarizes all types of changes in the user manual.
Version of the
manual
Date of issue
Description of changes
.
5/0/04
Added options Soft, Medium a Hard into the menu item Follow Spot
Mode.
.
0//04
Added Chapter 4.7 Installing handle (s) for Follow Spot Mode
Lamp remaining time - Alert icons added in the chapter "0.Error and in-
formation messages".
Modified menu Lamp On Time in menu Information
.3
05/0/05
DMX chart version 1.1 (LEE colour swatches added)
Specifications are subject to change without notice.
February 2, 2015