Eminere UV
11
3.4 The Booster box installation
ALWAYS DISCONNECT THE EMINERES UV FROM MAINS BEFORE
CONNECTING/DISCONNECTING THE BOOSTER BOX.
The Booster box falls under protection class I. Therefore, every Booster box
has to be connected to a mains socket outlet with a protective earthing connection.
1.Unscrew the four screws (1) from the cover (2) on the Booster box to get access to the terminal block (3) and
two mounting holes of diameter of 4.6 mm (4).
2. Screw the Booster box on a non-flammable flat surface and connect cables.
The Cable gland M20x1.5 for Power IN (5) is intended for a cable of a diameter of 7-13mm.
Remove the end cap from the cable gland before passing the cable.
Power connection
L
N
(earth)
Core (EU)
Braun
Blue
Green/yellow
Core (US)
Black
White
Green
We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland
before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the
gland body.