background image

 Eminere UV  

 

Table of contents 

 

 

1. Safety instructions ...................................................................................................................................................... 3 

2. Fixture exterior view ................................................................................................................................................... 5 

3. Installation .................................................................................................................................................................. 5 

3.1 Mounting the fixture ............................................................................................................................................ 5 

3.2 Connection to mains ............................................................................................................................................. 5 

3.3 The Booster box .................................................................................................................................................... 9 

3.4 The Booster box installation ............................................................................................................................... 11 

3.5 Jumper cable assembling .................................................................................................................................... 13 

4. Technical specifications ............................................................................................................................................ 16 

5. Cleaning and maintenance ....................................................................................................................................... 20 

5.1 Disposing of the product .................................................................................................................................... 20 

6. ChangeLog ................................................................................................................................................................ 20 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ANOLiS Eminere Remote UV 2

Страница 1: ...Preliminary version ...

Страница 2: ...r view 5 3 Installation 5 3 1 Mounting the fixture 5 3 2 Connection to mains 5 3 3 The Booster box 9 3 4 The Booster box installation 11 3 5 Jumper cable assembling 13 4 Technical specifications 16 5 Cleaning and maintenance 20 5 1 Disposing of the product 20 6 ChangeLog 20 ...

Страница 3: ...S LUMINAIRE IS DESIGNED WITH UV LEDS AND MUST BE INSTALLED IN COMPLIANCE WITH COMPETENT TECHNICAL DIRECTIONS TO PREVENT THE USER S EYE AND BARE SKIN FROM EXPOSURE TO HARMFUL UV RADIATION CE LUMINAIRE EST CONCU POUR ETRE UTILISE AVEC DES LED UV ET DOIT ETRE INSTALLE EN STRICTE CONFORMITE AVEC LES INSTRUCTIONS AFIN D EVITER QUE LES YEUX OU LA PEAU L UTILISATEUR NE SOIENT EXPOSES AUX EFFETS NEFASTES ...

Страница 4: ...re becomes hot during operation Allow the fixture to cool approximately 30 minutes prior to servicing or maintenance Operate the fixture only after having familiarized yourself with its functions Do not permit operation by persons not qualified to operate the fixture Most damages are the result of unprofessional operation Immunity of the equipment is designed for electromagnetic environments E1 E2...

Страница 5: ... access to mounting brackets 5 Ensure that the structure to which you are attaching the unit is secure 3 2 Connection to mains The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations This device falls under class one and must be grounded 1 Transparent glass cover 2 LED module 3 Output connector 4 Input connec...

Страница 6: ...d outdoor The output panel connector at last fixture in the Eminere UV chain has to always be covered with the water tight cap to keep declared IP rating The Eminere UV modules should be connected to the E box which allows power supply of the Eminere UV modules and their control Do not connect disconnect Emineres UV to the E box or Booster box and each other when they are under voltage When you ch...

Страница 7: ...Eminere UV 7 E box Star E box Pro ...

Страница 8: ...g tables apply for the Standard mode of E boxes EMINERE UV 2 Voltage Cable length 120V 190V 230V 277V 10 m 41 64 78 94 20 m 41 64 78 94 30 m 28 64 78 94 50 m 17 43 63 91 70 m 12 31 45 65 100 m 9 21 31 46 200 m 4 11 16 23 EMINERE UV 4 Voltage Cable length 120V 190V 230V 277V 10 m 21 33 40 48 20 m 21 33 40 48 30 m 15 33 40 48 50 m 9 22 32 47 70 m 6 16 23 38 100 m 4 11 16 23 200 m 2 5 8 12 Cable leng...

Страница 9: ...alled in the chain of Emineres UV at one LED output of the E box The following tables apply for the Standard mode of E boxes EMINERE UV 2 Max number of Emineres UV 2 94 Voltage Cable length 120V 190V 230V 277V 10 m 41 82 64 78 20 m 41 82 64 78 30 m 28 56 84 64 78 50 m 17 34 51 68 85 43 86 63 91 70 m 12 24 36 48 60 72 84 31 62 93 45 90 65 100 m 9 18 27 36 45 54 60 72 81 90 21 42 63 84 31 62 93 46 9...

Страница 10: ...10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 5 10 15 20 25 30 35 40 45 8 16 24 32 40 12 24 36 Example E box Daisy Power supply 230V Cable length 70m fixture Eminere UV 2 The Booster box has to be connected after every 45th Eminere UV 2 fixture 45 and fixture 90 from 94 fixtures ...

Страница 11: ...ck 3 and two mounting holes of diameter of 4 6 mm 4 2 Screw the Booster box on a non flammable flat surface and connect cables The Cable gland M20x1 5 for Power IN 5 is intended for a cable of a diameter of 7 13mm Remove the end cap from the cable gland before passing the cable Power connection L N earth Core EU Braun Blue Green yellow Core US Black White Green We recommend to apply an adequate la...

Страница 12: ... diameter of 6 12mm for smaller diameter of cable 4 8mm you have to remove the original seal from the cable gland M20 and use the enclosed reducing seal instead of it The reducing seal for diameter of cable 4 8mm P N 13051388 is enclosed in the Booster box 3 Screw the cover 2 back on the Booster box ...

Страница 13: ...13053139 The seal with inner diameter of 14 5 mm serves for cable of diameter 10 14 5mm The seal with inner diameter of 10 mm serves for cable of diameter 8 10mm Parts of the connector 2 Put the seiling circle 2 on the connector with screws 1 3 Remove insulation from the cable 6 and from individual wires and fasten three terminals on data wires CE version Detail of Sealing circle 2 placing ...

Страница 14: ...Put parts of the connector on the cable 6 and connect wires to the connector First connect power wires L N Earth and after that data wires D D 0V Avoid excessive torsion of data wires CE version Male Female US version Male Female ...

Страница 15: ...rew the clamp ring 3 to the connector 1 insert the seal 4 to the clamp ring 3 and tighten the sealing nut 5 enough During the steps DO NOT TWIST the cable 6 7 Use the same procedure to assemble the connector on the second end of the cable IMPORTANT Do not bend the cable near to the connector minimum distance for bending is 50mm ...

Страница 16: ...Output 1 Main power Input Control DMX Art Net sACN W DMX control RDM Pixel control 1px 1ft 120 277V Input Connection via terminal blocks inlets via grommet IP67 E box Star 6 outputs 1 Main power Input Control DMX Art Net sACN W DMX control RDM Pixel control 1px 1ft 120 277V Input Connection via terminal blocks inlets via grommet IP67 E box Pro 6 outputs 6 Main power Inputs Control DMX Art Net sACN...

Страница 17: ...onvection Total heat dissipation Eminere UV 2 113 BTU h calculated Eminere UV 4 214 BTU h calculated Protection factor CE IP 67 US Suitable for wet location Impact rating CE IK06 Operating ambient temperature range 20 C 40 C 4 F 104 F Operating temperature 67 C Ambient 40 C 153 F Ambient 104 F Connection Input panel connector Amphenol ABAB DMQ06000021 IN P N13052952 Output panel connector Amphenol...

Страница 18: ...Eminere UV 18 Dimensions All dimensions in mm inch ...

Страница 19: ... Leader Cable FF 2m P N 13053005 Leader Cable FF 5m P N 13053006 Leader Cable FF 10m P N 13053007 Leader Cable FF 25m P N 13053008 Leader Cable FF 50m P N 13053009 US Leader Cables FF Leader Cable FF 2m P N 13053010 Leader Cable FF 5m P N 13053011 Leader Cable FF 10m P N 13053012 Leader Cable FF 25m P N 13053013 ...

Страница 20: ...er for Eminere 2 RAL9011 P N 10980485 Cable Cover for Eminere 4 RAL9011 P N 10980487 Shield for Eminere 2 RAL9011 P N 10980489 Shield for Eminere 4 RAL9011 P N 10980491 5 Cleaning and maintenance DANGER Disconnect from the mains before starting any maintenance or cleaning work Rinse off loose dirt with low pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive wa...

Страница 21: ...1 Specifications are subject to change without notice February 23 2022 Copyright 2019 2022 Robe Lighting All rights reserved Made in CZECH REPUBLIC by ROBE LIGHTING s r o Palackeho 416 20 CZ 75701 Valasske Mezirici ...

Отзывы: