Eminere
11
EMINERE 4
Max. number of Emineres 4= 48
Voltage
Cable
length
120V
190V
230V
277V
10 m
21,42
33
40
-
20 m
21,42
33
40
-
30 m
15,30,45
33
40
-
50 m
9,18,27,36,45
22,44
32
47
70 m
6,12,18,24,30,36,42
16,32
23,46
38
100 m
4,8,12,16,20,24,28,32,36,
40,44
11,22,33,44
16,32
23,46
200 m
2,4,6,8,10,12,14,16,18,20,
22.24.26,28,30,32,34,36,38
40,42,44,46
5,10,15,20,25,30
35,40,45
8,16,24,32,40
12,24,36
Example: E-box Daisy, Power supply= 230V, Cable length=70m, fixture=Eminere 2
The Booster box has to be connected after every 45th Eminere 2 (fixture 45 and fixture 90) from 94 fixtures.
3.4 The Booster box installation
ALWAYS DISCONNECT THE EMINERES FROM MAINS BEFORE
CONNECTING/DISCONNECTING THE BOOSTER BOX.
The Booster box falls under protection class I. Therefore, every Booster box
has to be connected to a mains socket outlet with a protective earthing connection.
1.Unscrew the four screws (1) from the cover (2) on the Booster box to get access to the terminal block (3) and
two mounting holes of diameter of 4.6 mm (4).
2. Screw the Booster box on a non-flammable flat surface and connect cables.