background image

 

 

/

 

RP750x

 

R01

 

0000

 

1213

 

5/17

 

Copyright

 

©

 

2013

 

ROAM

 

Data

 

 

 

All

 

rights

 

reserved

 

3.

 

Recommendations

 

3.1.

 

Safety

 

 

Lithium

 

battery

 

RP750xis

 

fitted

 

with

 

a

 

lithium

 

battery

 

which

 

is

 

not

 

accessible

 

to

 

the

 

user.

 

Only

 

a

 

qualified

 

technician

 

is

 

authorized

 

to

 

open

 

the

 

unit

 

and

 

change

 

this

 

component.

 

Battery

 

RP750x

 

is

 

fitted

 

with

 

a

 

rechargeable

 

Lithium

ion

 

battery

 

specifically

 

designed

 

for

 

this

 

terminal.

  

It

 

is

 

not

 

accessible

 

to

 

the

 

user.

 

 

Only

 

use

 

chargers

 

with

 

rating

 

that

 

match

 

the

 

power

 

ratings.

 

 

Do

 

not

 

attempt

 

to

 

open

 

the

 

terminal.

 

 

Do

 

not

 

store

 

your

 

terminal

 

unattended

 

in

 

a

 

vehicle.

 

 

If

 

the

 

battery

 

has

 

to

 

be

 

replaced,

 

this

 

operation

 

requires

 

to

 

be

 

performed

 

by

 

qualified

 

staff.

 

 

Warning

 

Risk

 

of

 

explosion

 

if

 

battery

 

is

 

replaced

 

by

 

an

 

incorrect

 

type,

 

do

 

not

 

disassemble,

 

use

 

specified

 

charger

 

only,

 

do

 

not

 

short

circuit,

 

do

 

not

 

dispose

 

of

 

in

 

fire,

 

do

 

not

 

throw

 

in

 

water,

 

dispose

 

of

 

used

 

batteries

 

according

 

to

 

the

 

instructions.

 

 

3.2.

 

Security

 

of

 

your

 

terminal

 

Upon

 

receipt

 

of

 

your

 

terminal

 

you

 

should

 

check

 

for

 

signs

 

of

 

tampering

 

of

 

the

 

equipment.

 

It

 

is

 

strongly

 

advised

 

that

 

these

 

checks

 

are

 

performed

 

regularly.

 

You

 

should

 

check,

 

for

 

example:

 

that

 

the

 

keypad

 

is

 

firmly

 

in

 

place;

 

that

 

there

 

is

 

no

 

evidence

 

of

 

unusual

 

wires

 

that

 

have

 

been

 

connected

 

to

 

any

 

ports

 

on

 

your

 

terminal

 

or

 

associated

 

equipment,

 

the

 

chip

 

card

 

reader,

 

or

 

any

 

other

 

part

 

of

 

your

 

terminal.

 

Such

 

checks

 

would

 

provide

 

warning

 

of

 

any

 

unauthorised

 

modifications

 

to

 

your

 

terminal,

 

and

 

other

 

suspicious

 

behaviour

 

of

 

individuals

 

that

 

have

 

access

 

to

 

your

 

terminal.

 

Your

 

terminal

 

detects

 

any

 

“tampered

 

state”.

 

In

 

this

 

state

 

the

 

terminal

 

will

 

repeatedly

 

flash

 

the

 

message”

 

Alert

 

Interruption!”

 

and

 

further

 

use

 

of

 

the

 

terminal

 

will

 

not

 

be

 

possible.

 

If

 

you

 

observe

 

the

 

“Alert

 

Interruption!”

 

message,

 

you

 

should

 

contact

 

the

 

terminal

 

helpdesk

 

immediately.

 

You

 

are

 

strongly

 

advised

 

to

 

ensure

 

that

 

privileged

 

access

 

to

 

your

 

terminal

 

is

 

only

 

granted

 

to

 

staff

 

that

 

have

 

been

 

independently

 

verified

 

as

 

being

 

trustworthy.

 

 

CAUTION

 

NEVER

 

ask

 

the

 

customer

 

to

 

divulge

 

their

 

PIN

 

Code.

 

Customers

 

should

 

be

 

advised

 

to

 

ensure

 

that

 

they

 

are

 

not

 

being

 

overlooked

 

when

 

entering

 

their

 

PIN

 

Code

.

 

 

 

 

 

Содержание RP750C

Страница 1: ...ROAM 280 Summer St Boston MA 02210 Phone 1 888 589 5885 RP750x U S E R G U I D E...

Страница 2: ..._____________________ 10 4 5 Connection _________________________________________________________ 11 4 5 1 USB cable connection___________________________________________________________ 11 4 5 2 Cabl...

Страница 3: ...In order to benefit from the product related guaranteeand to respect security we ask you to use only accessories delivered in box with the product entrusting maintenance operations only to an authori...

Страница 4: ...RP cluded in th le might also via audio jac ered with a p ure optimum ot alter in an 4 17 al packaging P750c RP75 e RP750xbo o be include ck protective s m protection yway the us USB g It must be 5x...

Страница 5: ...of your terminal you should check for signs of tampering of the equipment It is strongly advised that these checks are performed regularly You should check for example that the keypad is firmly in pl...

Страница 6: ...equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one...

Страница 7: ...RP750x R01 0000 1213 7 17 Copyright 2013 ROAM Data All rights reserved This equipment is compliant with System specification BLE 4 0 xxxx xxxx SSP protocol...

Страница 8: ...re Weight 95 35g Dimensions L x w x h 101 2mm x 56 5mm x 17mm Battery Li ion 450mAh Operating conditions Operating temperature 0 C to 50 C charging 10 C 45 C standalone Connections on terminal Micro U...

Страница 9: ...r a tablet into a powerful secure POS solution 4 2 Charging Terminal Before using the terminal for the first time it requires to be charged for about 3 hours via a computer USB port power output of 45...

Страница 10: ...terminal m of the dev button using the reb ration befor 10 17 ways place t and electrom IN Persona terminal pre fter a time he device be required vice next to t boot switch re it he terminal magnetic...

Страница 11: ...4 5 1 USB cable connection A USB connector is located on the bottomof the terminal Present the device in front of the connector and plug it CAUTION Use only ROAM cable or accessory not to void warran...

Страница 12: ...ressing the Bluetooth button for 2 seconds The Bluetooth button can be found in the lower left corner of the keypad The Bluetooth button is shared with the button This will bring the Bluetooth option...

Страница 13: ...etic Swipe 01 0000 1213 Termin ypad consis Slot nalkeypad sts in 15 keys 13 17 d s Cancel and Clear key Numeric k Validation d Power Off keys and Power On Copyright 2 Al n key C 2013 ROAM Data l right...

Страница 14: ...nually in the swiping slot at the top of the terminal magstripe facingup as illustrated below Swipe the card with constant speed not too slow not too fast for optimum reading accuracy 5 4 2 Inserting...

Страница 15: ...ation 6 3 Troubleshooting The terminal does not turn on Battery level is too low Check the USB connection Make sure the PC is turned on Check that the wall plug PSU is fully inserted in the electrical...

Страница 16: ...es The associated symbol means that WEEE and waste batteries must not be thrown away but collected separately and recycled ROAM ensures that efficient collection and recycling schemes are set up for W...

Страница 17: ...ROAM If such permission is granted it will be subject to the condition that the recipient ensures that any other recipient of this document or information contained therein is held responsible to ROA...

Отзывы: