1 Introduction
Manual TRZ 03· EN08 ·2018 September, 10th
23
Calculation:
Z
p(total)
= 3000 + 1260
= 4260
4
2
150
650
3
,
1
4260
=
p
= 4,2 mbar
1.12 Pressure tap
A pressure tap has been provided to connect the pressure transducer of a volume
corrector or a pressure gauge to read the pressure at measurement conditions
prevailing
inside the gas meter. This pressure tap is identified by “p
r
”.
1.13 Using gas meters with different types of
gases
Gas type
Symbol Density
at 0°C
1,013
bar
Meter
housing
Comments
Acid gas
Special
Special measuring element
Air
1,29
Standard
Ammonia
NH
3
0,77
Standard O-rings / lubrication
Argon
Ar
1,78
Standard
Butane
C
4
H
10
2,70
Standard
Carbon dioxid
CO
2
1,98
Standard Excepion: food industry
Carbon monoxid
CO
1,25
Standard
Ethan
C
2
H
6
1,36
Standard
Ethylene (gaseous) C
2
H
4
1,26
Standard Special design
Freon (gaseous)
CCI
2
F
2
5,66
Standard O-rings / lubrication
Helium
He
0,18
Standard Reduced measuring range
Hydrogen
H
2
0,09
Special
Reduced measuring range
Hydrogen sulphide
(0,2%)
H
2
S
1,54
Special
Special measuring element
Methane
CH
4
0,72
Standard
Nitrogen
N
2
1,25
Standard