background image

Caution: Switch off the main power while doing the Power Connection.

Step 1:

 Wall mount the Indicator unit nearby motor pump switch/starter location. 

The location chosen should be near the window or in open space to ensure good 
signal strength.

Step 2:

 Connect AC supply (AC 230V) to 1st and 2nd terminal of the indicator as 

shown in the gure1.

Step 3: 

Unscrew the top panel of transmitter. There is a battery holder inside it. 

Put the given Li-ion battery inside the case, according to polarity. RF Signal LED 
blinks once.

4. INSTALLATION

2

 PROCEDURE

Step 4: 

Power ON the indicator. Power ON LED glows in indicator. Take the 

transmitter near the tank. To check the communication between transmitter 
and Indicator Press the push button inside transmitter for more than 16 
seconds. RF Signal LED blinks two times with 5 seconds interval. This ensures 
the perfect communication between them.

Step 5:

 Now power off the indicator unit. 

Contact type sensor connection:

 Take 

the sensors and cut them according to the levels of the tank and join them with 
the sensors lines of transmitter as per color coding. (Refer gure2). 

Magnetic 

oat sensor connection:

 These sensors has 2 wires. Use any one wire in each 

sensor as common. Other wire left in each can be used for levels.

Step 6:

 Immerse the sensors in the water tank and place at 20%, 40%, 60%, 

80% and 100% levels.  (Refer gure2)

Note:

 Follow Step 5 and 6 for other tanks.(If you have multi-tank models)

Step 7:

 Close the top panel of the transmitter using the screws. Place the solar 

panel facing sun light using the double side tape.
This completes the installation.

Figure1: Indicator

Figure2: Transmitter

water 
Inlet

(Black)CN

(Brown) 20%

(Red) 40%

(Orange) 60%

(Yellow) 80%

(Green) 100%

AC 

230V

PHASE

NEUTRAL