background image

4. OPERATING PROCEDURE

Ÿ

Switch ON POWER button of the indicator unit.

Ÿ

In  indicator  unit  depending  upon  the  water  levels  in  each  tank,  the  level 
indication  LEDs  are  ON.  Furthermore,  the  levels  of  the  each  tank  will  be 
monitored  every  16  seconds  and  updates  the  indicator  whenever  there  is 
change in the water level  . If the water level goes low, all LEDs will be OFF and 
you will hear a low beep alarm for 60 seconds. If water goes to high level all LEDs 
will be ON and you can hear a fast beep alarm for 60 seconds.

3

5. OPERATING PROCEDURE

6. TROUBLE SHOOTING METHODS

S. No. Error

Solutions

1

No 
communication 
between the 
indicator and 
transmitter

a.

 Check whether any obstrucles are there in 

between transmitter and receiver units like large 
trees, buildings etc.

b.

 Check the battery in transmitter is connected 

correctly without any loose act. 

c.

 Check whether the battery is completely drained 

out, If so charge the battery using the USB port in 
it.

2

Tank level 
indicator LEDs 
are off

If one or all the level indicator LEDs are not glowing,

a.

 Check common sensor connection is correctly 

made. If any loose contact correct it. 

b.

 Check all the sensor connections are having any 

loose contact. Also check if the cable lines are 
intact.

Pairing Procedure:

The units are generally paired and dispatched. In case of any trouble at the 
time of installation, users can pair the units once again.

Ÿ

·In Indicator Unit, Press the GREEN SET button and do not take the nger 
out. While doing this, switch ON the power ON/OFF switch. All the tank level 
LEDs will blink. It means the device is ready for pairing.

Ÿ

·In Transmitter Unit, there is a Push button inside it. By pressing the push 
button without taking out the nger, insert the battery into the battery 
case. Now the RF Signal LED inside transmitter blinks one time and all the 
tank level LEDs goes off in the controller unit. Thus pairing is completed.   

Отзывы: