5. Rotate the encoder to change the setting and confirm by pushing the encoder again.
To adjust the output line level on the web remote:
1. Select either a single channel or two channels by clicking the corresponding level meter. All inputs
between the two selected channels will be automatically included in the selection.
2. Press one of the corresponding buttons for
+13 dBu
,
+19 dBu
or
+24 dBu
. The selected value is
shown within the level meter.
10.1.2. Mute Analog Outputs
To mute an individual output channel on the device:
1. Open the
Analog Output Configuration
tab in the
OUTPUT
section
2. Initially, the cursor will highlight all output channels. Press the encoder, then rotate the encoder to
move the cursor to the channel that should be muted.
Cursor (current channel)
Input Reference Level
Channel Mute
3. Move the cursor to
Mute
Toggle and push it.
To adjust the output line level on the web remote:
1. Select either a single channel or two channels by clicking the corresponding level meter. All inputs
between the two selected channels will be automatically included in the selection.
2. Toggle the
Mute
switch. The status is reflected with a red
M
in the corresponding level meters.
10.2. MADI Outputs
The MADI outputs of the M-32 DA Pro are always active. If no routing is configured, an empty stream is
sent that can be used for clocking. This state is represented with a light-green Status Indicator.