![RME Audio Hammerfall HDSP 9652 Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/rme-audio/hammerfall-hdsp-9652/hammerfall-hdsp-9652_user-manual_1467368071.webp)
User's Guide HDSP System HDSP 9652
© RME
71
30. Technical Background
30.1 Lock and SyncCheck
Digital signals consist of a carrier and the data. If a digital signal is applied to an input, the re-
ceiver has to synchronize to the carrier clock in order to read the data correctly. To achieve this,
the receiver uses a PLL (Phase Locked Loop). As soon as the receiver meets the exact fre-
quency of the incoming signal, it is locked. This
Lock
state remains even with small changes of
the frequency, because the PLL tracks the receiver's frequency.
If an ADAT or SPDIF signal is applied to the HDSP 9652, the unit indicates LOCK, i. e. a valid
input signal. This information is presented in the HDSP 9652's Settings dialog. In the status
display
SyncCheck,
the state of all clocks is decoded and shown as simple text (No Lock, Lock,
Sync).
Unfortunately, LOCK does not necessarily mean that the received signal is correct with respect
to the clock which processes the read out of the embedded data. Example [1]: The HDSP 9652
is set to 44.1 kHz internally (clock mode Master), and a mixing desk with ADAT output is con-
nected to input ADAT1. The status display will show LOCK immediately, but usually the mixing
desk's sample rate is generated internally (it is Master too), and thus slightly higher or lower
than the HDSP 9652's internal sample rate. Result: When reading out the data, there will fre-
quently be read errors that cause clicks and drop outs.
Also when using multiple inputs, a simple LOCK is not sufficient. The above described problem
can be solved elegantly by setting the HDSP 9652 from Master to AutoSync (its internal clock
will then be the clock delivered by the mixing desk). But in case another un-synchronous device
is connected, there will again be a slight difference in the sample rate, and therefore clicks and
drop outs.
In order to display those problems, the HDSP 9652 includes
SyncCheck
®
. It checks all clocks
used for
synchronicity
. If they are not synchronous to each other, the status display will show
LOCK. If they are synchronous to each other (i. e. absolutely identical) the status display will
change to SYNC. In example 1 it would have been obvious that the entry LOCK is shown in
SyncCheck
right after connecting the mixing desk.
In practice, SyncCheck allows for a quick overview of the correct configuration of all digital de-
vices. So one of the most difficult and error-prone topics of the digital studio world finally be-
comes easy to handle.
Содержание Hammerfall HDSP 9652
Страница 5: ...User s Guide HDSP System HDSP 9652 RME 5 User s Guide HDSP 9652 General...
Страница 11: ...User s Guide HDSP System HDSP 9652 RME 11 User s Guide HDSP 9652 Driver Installation and Operation Windows...
Страница 29: ...User s Guide HDSP System HDSP 9652 RME 29 User s Guide HDSP 9652 Driver Installation and Operation Mac OS X...
Страница 38: ...38 User s Guide HDSP System HDSP 9652 RME...
Страница 39: ...User s Guide HDSP System HDSP 9652 RME 39 User s Guide HDSP 9652 Connections and TotalMix...
Страница 45: ...User s Guide HDSP System HDSP 9652 RME 45...
Страница 66: ...66 User s Guide HDSP System HDSP 9652 RME...
Страница 67: ...User s Guide HDSP System HDSP 9652 RME 67 User s Guide HDSP 9652 Technical Reference...
Страница 75: ...User s Guide HDSP System HDSP 9652 RME 75 31 Block Diagram HDSP 9652...