Indicator
Color
LED
Descrip�on
FXL
GRN
ON
Blinking
OFF
Fiber port link OK
Fiber port link OK and ac�vity is present
Fiber port link fail
FDX
GRN
ON
OFF
Blinking
Fiber port at full duplex
Fiber port at half duplex
Fiber port at half duplex and collisions occurring
FSD
GRN
ON
OFF
Fiber signal detected
Fiber disconnected
FEFD
GRN
OFF
Blinking
Normal opera�on
Far end fault detected
TDX
GRN
ON
OFF
Blinking
TP port at full duplex
TP port at half duplex
TP port at half duplex and collisions occurring
PWR
GRN
ON
OFF
Card power is ON
Card power is OFF
10/100
ORG
ON
OFF
TP port speed is 100M
TP port speed is 10M
LINK/ACT
GRN
ON
Blinking
OFF
TP port link OK
TP port link OK and ac�vity is present
TP port link not present
If trouble is encountered, verify all copper and fiber connec�ons
and se�ngs. If any of the DIP switches were changed, recycle the
power to the card by flipping switch 6 (Reset) from RST to ON then
back to RST. Refer to the LED Indicators on the front panel, they
show availability of power, modes of opera�on, and data being
received by the fiber and TP port.
If trouble persists, replace the unit and retest. If technical assistance
is required, contact RLH Industries, Inc. technical support
department*.
*Tech support contact info is at the end of this document
Troubleshooting