When connec�ng a 2-wire transmi�er to the RLH fiber transmi�er (AD-420TX-XX-X), the RLH transmi�er is always a
sinking input, expec�ng the source voltage or current to be supplied by the remote device. In this example, the
2-wire transmi�er has 24VDC loop voltage provided by a separate power supply.

4~20mA System – 2-Wire Transmitter Wiring

System Diagram

By u�lizing fiber op�c cable, the 4~20mA Analog Signal system provides absolute electrical isola�on between both ends of
the communica�ons network. It is immune to EMI/RF interference, ground loops, and high voltage surges from lightning or
ground faults, and is ideal in electrically noisy environments such as near large power sources, electrical motors, and radio
communica�ons equipment.

Network and control equipment in high voltage areas can be at risk due to Ground Poten�al Rise (GPR). A copper network
cable referenced to a remote ground can become a path for high voltages during a ground fault. Placement of all-dielectric
fiber op�c cable (instead of copper) completely eliminates the presence of a remote ground, which drama�cally increases
safety of personnel and reliability of equipment.

Applications

Содержание Analog Signal 4~20mA Fiber Link System

Страница 1: ...me Warranty Made in USA Key Features The Analog Signal DIN Fiber Link system transmits a 4 20mA analog signal over one op cal fiber It also offers a 12 bit signal resolu on and less than 0 2 source s...

Страница 2: ...ly use gradual and smooth bends to avoid damaging glass fiber Keep dust caps on fiber op c connectors at all mes when disconnected Do not remove dust caps from unused fiber Keep fiber ends and fiber c...

Страница 3: ...g fiber op c cable the 4 20mA Analog Signal system provides absolute electrical isola on between both ends of the communica ons network It is immune to EMI RF interference ground loops and high voltag...

Страница 4: ...input expec ng the source voltage or current to be supplied by the remote device 4 20mA System 4 Wire Transmitter Wiring When connec ng a 3 wire transmi er to the RLH fiber transmi er AD 420TX XX X th...

Страница 5: ...t or output contact terminals LED s and the TX or RX fiber port Front Panel 24VDC power source at both installa on sites DIN rail for moun ng or wall space for wall moun ng Mul meter Measure the DC vo...

Страница 6: ...lation cont d The DIN clip for moun ng the system is mounted onto the rear panel Hook the DIN clip on the top flange of the DIN rail and rotate to the locked posi on to install To remove push up to de...

Страница 7: ...into the connector before opera ng the system Requires one 1 24VDC power supply on each side of the system Fully seat the terminal block back into the connector before opera ng the system Installation...

Страница 8: ...r link OK Fiber link failed Input 4 20mA Input ON OFF Blinking Signal present No signal present Signal over range Output 4 20mA Output ON OFF Blinking Signal present No signal present Signal over rang...

Страница 9: ...eceiver Mul mode ST 2km 1 2 miles AD 420RX 04 1 Transmi er Singlemode SC 20km 12 4 miles AD 420TX 40 1 Receiver Singlemode SC 20km 12 4 miles AD 420RX 40 1 Transmi er Singlemode ST 20km 12 4 miles AD...

Страница 10: ...acy for Fiber Link System Both Transmi er Receiver Ambient Temp Effect 0 C to 70 C 0 2 Ambient Temp Effect 40 C to 0 C 2 0 Update Rate 1 3 Khz Signal Resolution 12 Bits Sensitivity 2 12 4096 Steps Vol...

Страница 11: ...Inc The leader in rugged fiber op c technology USER GUIDE By Email support fiberop clink com By Phone Toll Free 855 754 2497 855 RLH 24X7 Tech Support By FAX 714 532 1885 By Mail A Sales RLH Industrie...