RKI 65-2437RKSS-05 Скачать руководство пользователя страница 3

 

65-2437RKSS-05 CO Detector 

Product Warranty

RKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in 
materials, workmanship, and performance for a period of one year from date of shipment 
from RKI Instruments, Inc. Any parts found defective within that period will be repaired 
or replaced, at our option, free of charge. This warranty does not apply to those items 
which by their nature are subject to deterioration or consumption in normal service, and 
which must be cleaned, repaired, or replaced on a routine basis. Examples of such items 
are:

Warranty is voided by abuse including mechanical damage, alteration, rough handling, or 
repair procedures not in accordance with the operator’s manual. This warranty indicates 
the full extent of our liability, and we are not responsible for removal or replacement costs, 
local repair costs, transportation costs, or contingent expenses incurred without our prior 
approval.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER 
WARRANTIES AND REPRESENTATIONS, EXPRESSED OR IMPLIED, 
AND ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF 
RKI INSTRUMENTS, INC. INCLUDING BUT NOT LIMITED TO, THE 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE. IN NO EVENT SHALL RKI INSTRUMENTS, 
INC. BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL 
LOSS OR DAMAGE OF ANY KIND CONNECTED WITH THE USE OF 
ITS PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR 
OPERATE PROPERLY.

This warranty covers instruments and parts sold to users by authorized distributors, 
dealers, and representatives as appointed by RKI Instruments, Inc.

We do not assume indemnification for any accident or damage caused by the operation of 
this gas monitor, and our warranty is limited to the replacement of parts or our complete 
goods.

a) Absorbent cartridges

d) Batteries

b) Pump diaphragms and valves

e) Filter elements

c) Fuses

Содержание 65-2437RKSS-05

Страница 1: ...RKI Instruments Inc www rkiinstruments com 65 2437RKSS 05 Carbon Monoxide Detector Operator s Manual Part Number 71 0439 Revision P1 Released 9 14 17...

Страница 2: ...calibration and maintenance of the detector is essential for proper operation and correct readings Please calibrate and maintain this detector regularly Frequency of calibration depends upon the type...

Страница 3: ...t costs local repair costs transportation costs or contingent expenses incurred without our prior approval THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND REPRESENTATIONS EXPRES...

Страница 4: ...he CO Detector 4 Wiring the CO Detector to a Controller 5 Startup 7 Introducing Incoming Power 7 Setting the Zero Signal 7 Maintenance 8 Preventive Maintenance 8 Troubleshooting 9 Replacing Components...

Страница 5: ...e instructions and warnings in this manual to assure proper and safe operation of the 65 2437RKSS 05 and to minimize the risk of personal injury Be sure to maintain and periodically calibrate the 65 2...

Страница 6: ...on describes the components of the 65 2437RKSS 05 CO detector The 65 2437RKSS 05 consists of the 65 2438 CO detector and junction box Figure 1 CO Detector Component Location Stainless Steel J Box Lock...

Страница 7: ...ntly bonded to the cap Two wires extend from the top of the detector housing body Use these wires to connect the CO detector to the junction box terminal strip The housing includes a four socket patte...

Страница 8: ...the junction box A locking set screw on the junction box cover allows you to secure the junction box cover and prevent it from being removed Installation This section describes procedures to mount th...

Страница 9: ...source is OFF before you make wiring connections 1 Turn off the controller 2 Turn off or unplug power to the controller 3 Remove the junction box cover WARNING To maintain the explosion proof classif...

Страница 10: ...junction box cover to the junction box 7 Route the cable or wires leading from the CO detector through one of the conduit hubs at the controller housing Use appropriate conduit fittings and constructi...

Страница 11: ...the Zero Fresh Air Reading WARNING If the detector installation is explosion proof do not remove the detector housing cap or junction box cover while the circuits are energized unless the area is dete...

Страница 12: ...ble external alarms 2 Verify that the controller display reading for the channel you are testing is 0 If the display reading is not zero set the zero reading of the detector as described in the Start...

Страница 13: ...lt or Unable to Calibrate Detector responds slowly or does not respond during response test Unable to accurately set the zero or response reading during calibration Detector requires frequent calibrat...

Страница 14: ...in the detector housing 8 Make sure the cap gasket is in place and screw the detector housing cap back onto the detector housing body 9 Turn on or plug in power to the controller 10 Turn on the contro...

Страница 15: ...ect 8 Reinstall the junction box cover 9 Turn on or plug in power to the controller 10 Turn on the controller and place into normal operation CAUTION Allow the replacement detector to warm up for 5 mi...

Страница 16: ...he fixed flow regulator to the calibration cup 4 Put the controller into its calibration program Setting the Zero Reading NOTE If you can verify that the CO detector is in a fresh air environment you...

Страница 17: ...regulator from the cylinder 8 Remove the calibration cup from the detector NOTE For convenience leave regulator and calibration cup connected by the sample tubing 9 Allow about 45 seconds for the gas...

Страница 18: ...9 65 2437RKSS 05 CO Detector Operator s Manual this document 81 0064RK Calibration cylinder 50 PPM CO in air 17 liter 81 0064RK 01 Calibration cylinder 50 PPM CO in air 34 liter steel 81 0064RK 03 Cal...