background image

 

 

 

61-1000RK-05 Combustible Gas Detector• 2

 

Product Warranty

 

RKI Instruments, Inc., warranties gas alarm equipment sold by us to be free from defects 
in materials, workmanship, and performance for a period of one year from date of 
shipment from RKI Instruments, Inc. Any parts found defective within that period will be 
repaired or replaced, at our option, free of charge. This warranty does not apply to those 
items which by their nature are subject to deterioration or consumption in normal service, 
and which must be cleaned, repaired, or replaced on a routine basis. Examples of such 
items are:

Warranty is voided by abuse including mechanical damage, alteration, rough handling, or 
repair procedures not in accordance with the operator’s manual. This warranty indicates 
the full extent of our liability, and we are not responsible for removal or replacement costs, 
local repair costs, transportation costs, or contingent expenses incurred without our prior 
approval.

 

THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER 
WARRANTIES AND REPRESENTATIONS, EXPRESSED OR IMPLIED, 
AND ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF 
RKI INSTRUMENTS, INC., INCLUDING BUT NOT LIMITED TO, THE 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE. IN NO EVENT SHALL RKI INSTRUMENTS, 
INC., BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL 
LOSS OR DAMAGE OF ANY KIND CONNECTED WITH THE USE OF 
ITS PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR 
OPERATE PROPERLY.

 

This warranty covers instruments and parts sold to users by authorized distributors, 
dealers, and representatives as appointed by RKI Instruments, Inc.

We do not assume indemnification for any accident or damage caused by the operation of 
this gas monitor, and our warranty is limited to the replacement of parts or our complete 
goods.

a) Absorbent cartridges

d) Batteries

b) Pump diaphragms and valves

e) Filter elements

c) Fuses

Содержание 61-1000RK-05

Страница 1: ...www rkiinstruments com 61 1000RK 05 Combustible Gas Detector Operator s Manual Part Number 71 0087RK Revision A Released 12 14 05...

Страница 2: ...placement costs local repair costs transportation costs or contingent expenses incurred without our prior approval THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND REPRESENTATION...

Страница 3: ...unting the Combustible Gas Detector 6 Wiring the Combustible Gas Detector 7 Startup Introducing Incoming Power 9 Setting the Zero Signal 9 Maintenance 10 Preventive Maintenance 10 Troubleshooting 11 R...

Страница 4: ...ble gas detector Specifications WARNING Do not use this product in a manner not specified in this instruction manual Table 1 lists specifications for the combustible gas detector NOTE The following sy...

Страница 5: ...low you to mount the combustible gas detector into the bottom conduit hub of the junction box A rainshield screws onto the bottom of the detector The rainshield helps protect the detector from debris...

Страница 6: ...ing when you select the mounting site Select a site where the detector is not likely to be bumped or disturbed Make sure there is sufficient room to perform start up maintenance and calibration proced...

Страница 7: ...hielded cable or four wires in conduit through the top conduit hub of the junction box WARNING To maintain the explosion proof classification of the LEL detector junction box combination a conduit sea...

Страница 8: ...stible Gas Detector 8 Figure 2 Wiring the Combustible Gas Detector to a Controller Combustibles Detector DetectorWires Controller LEL Detector Terminals Green Red Green Red Terminal Strip Black White...

Страница 9: ...tion manual CAUTION Allow the detector to warm up for 5 minutes before you continue with the next section Setting the Zero Reading Setting the Zero Reading CAUTION If you suspect the presence of combu...

Страница 10: ...xternal alarms before performing this test 1 Place the controller into its calibration program or disable external alarms 2 Verify that the controller display reading is 0 LEL If the controller readin...

Страница 11: ...p 4 Table 2 Troubleshooting the Combustible Gas Detector Condition Symptom s Probable Causes Recommended Action Fail Condition Controller indicates a fail condition The detector wiring is disconnected...

Страница 12: ...arms NOTE Calibrating the combustible detector may cause alarms Be sure to put the controller into its calibration program or disable external alarms before continuing Setting the Zero Reading CAUTION...

Страница 13: ...of the calibration kit in a safe and convenient place Parts List Table 3 lists replacement parts and accessories for the 61 1000RK 05 combustible gas detector Table 3 Parts List Part Number Descriptio...

Отзывы: