1. OUTLINE 

The temperature control module for DeviceNet V-TIO-J/V-TIO-K 
can send and receive data to/from DeviceNet compatible 
programmable controller (PLC) by the DeviceNet that is a 
multi-vendor compatible open field network. 
One V-TIO-J/V-TIO-K module enables temperature control 
corresponding to two channels. It has power supply and 
communication terminals in addition to temperature control input 
and output terminals.   
All data are set by communication.   

 

 

Master 

Control output

Measured 

input 

Power supply 

(24 V DC) 

Usable modules: 

• 

Temperature control module   
[Basic type]: 

V-TIO-A/V-TIO-C

• 

Temperature control module   
[Extension type]:  V-TIO-B/V-TIO-D

(Up to 30 modules) 

DeviceNet 

Temperature control 

module for DeviceNet 

V-TIO-J/V-TIO-K 

Programmable  

controller (PLC) 

Slave

 

 

For details when dividing two or more temperature 
control modules into some groups and then installed, 
see the 

Module Type Controller SRV DeviceNet 

Communication Instruction Manual (IMS01P11-E )

.

 

 

For details, see the 

Module Type Controller SRV 

DeviceNet

 

Communication Instruction Manual 

(IMS01P11-E )

.

 

For host communication using host communication 
terminals, see the 

Appendix B of

 

Module Type 

Controller SRV DeviceNet Communication 
Instruction Manual (IMS01P11-E )

 and the 

Module 

Type Controller SRV Communication Instruction 
Manual (IMS01P01-E )

.

 

 

 

2. PRODUCT CHECK 

Before using this product, check each of the following: 

• 

Model code 

• 

Check that all of the accessories delivered are complete. 

• 

Check that there are no scratch or breakage in external 
appearance (case, front panel, or terminal, etc). 

V–TIO–     

 –      N N N – N N –   –   

(1) (2)  (3) 

(4) (5) 

(6)  (7) 

(1) Type 

J:  Module for DeviceNet, heat control 
K:  Module for DeviceNet, heat/cool control 

(2) Control action 

(Each channel common code)

 

[For heat control]

 

F:  PID action with autotuning (AT) (reverse action) 
D:  PID action with autotuning (AT) (direct action) 
[For heat/cool control] 
B:  Heat/cool PID action with autotuning (AT) (air cooling) 
W: Heat/cool PID action with autotuning (AT) (water cooling) 

 

 

(3) Input range 

(Each channel common code)

 

[Thermocouple input] 

Type

Code

Range Code 

Range 

K02

0 to 400 

°

KB9 

32 to 752 

°

 

K04

0 to 800 

°

KB8 

32 to 1472 

°

 K16

200 to 

+

1372 

°

C KB7 

328 to 

+

2501 

°

F

 

K09

0.0 to 400.0 

°

KC2 

32.0 to 752.0 

°

F

 K35

200.0 to 

+

400.0 

°

C KC1 

328.0 to 

+

752.0 

°

F

J02

0 to 400 

°

JC2 

32 to 752 

°

 

J04

0 to 800 

°

JC1 

32 to 1472 

°

 J15

200 to 

+

1200 

°

C JB9 

328 to 

+

2192 

°

F

 

J09

0.0 to 400.0 

°

JC4 

32.0 to 752.0 

°

F

 J27

200.0 to 

+

400.0 

°

C JC3 

328.0 to 

+

752.0 

°

F

T08

0 to 400 

°

TB9 

32 to 752 

°

 

T09

0 to 200 

°

TC1 

32 to 392 

°

 T16

200 to 

+

400 

°

C TB8 

328 to 

+

752 

°

 

T06

0.0 to 400.0 

°

TC3 

32.0 to 752.0 

°

F

 T19

200.0 to 

+

400.0 

°

C TC2 

328.0 to 

+

752.0 

°

F

E01

0 to 800 

°

EA8 

32 to 1472 

°

 

E02

0 to 1000 

°

EA7 

32 to 1832 

°

S05

0 to 1768 

°

SA6 

32 to 3214 

°

R06

0 to 1768 

°

RA6 

32 to 3214 

°

N02

0 to 1300 

°

NA6 

32 to 2372 

°

B03

0 to 1800 

°

BB1 

32 to 3272 

°

PL

A02

0 to 1390 

°

AA6 

32 to 2534 

°

W5Re/
W26Re

W03

0 to 2300 

°

WA9 

32 to 4172 

°

[RTD input] 

Type

Code

Range Code 

Range 

Pt100

D17

0 to 400 

°

DC5 

32 to 752 

°

 

D33

0 to 850 

°

DC4 

32 to 1562 

°

 

D16

0.0 to 400.0 

°

C  DC7 

32.0 to 752.0 

°

F

 D28

200.0 to 

+

400.0 

°

C DC6 

328.0 to 

+

752.0 

°

F

JPt100

P17

0 to 400 

°

PC5 

32 to 752 

°

 

P23

0 to 600 

°

PC4 

32 to 1112 

°

 

P16

0.0 to 400.0 

°

PC7 

32.0 to 752.0 

°

F

 P28

200.0 to 

+

400.0 

°

C PC6 

328.0 to 

+

752.0 

°

F

[Voltage/current input] 

 Code

Type 

Code  Type 

Voltage

201

0 to 100 mV DC 

401 

0 to 5 V DC 

 

501

0 to 10 V DC 

601 

1 to 5 V DC 

Current

701

0 to 20 mA DC 

801 

4 to 20 mA DC 

(4) Control output (CH1),  (5) Control output (CH2) 

M: Relay contact output    V:  Voltage pulse output 0/12 V DC 
4:  0 to 5 V DC 

5:  0 to 10 V DC 

6:  1 to 5 V DC 

7:  0 to 20 mA DC 

8:  4 to 20 mA DC 

(6) CT type 

(Each channel common code)

 

P:  CTL-6-P-N (for 0 to 30 A) 

S:  CTL-12-S56-10L-N (for 0 to 100 A) 

(7) DeviceNet connector type 

N:  Open-style connector (Unshielded type) 
1:  Micro-style connector (Shield type) 

 

For heat/cool PID control (V-TIO-K), input channel 2 
becomes unused. 

 

For heat/cool PID control (V-TIO-K), Control output 
(CH1) corresponds to the heating output and 
Control output (CH2) corresponds to the cooling 
output. 

 

Heater break alarm function can not be used when 
control output is voltage/current output. 

 
 
 
 
 
 
 
 

 

If any of the products are missing, damaged, or if your 
manual is incomplete, please contact RKC sales office 
or the agent.

 

 

 

 

 

 

Accessories

 

Floppy disk (EDS file)................................................. 1 
End Plate.................................................................... 2 
Joint connector cover ................................................. 2 
Instruction Manual (IMS01P10-E1)............................ 1 

 

 

Содержание V-TIO-J

Страница 1: ...panel All high voltage connections such as power supply terminals must be enclosed in the instrumentation panel to avoid electric shock by operating personnel All precautions described in this manual...

Страница 2: ...K K02 0 to 400 C KB9 32 to 752 F K04 0 to 800 C KB8 32 to 1472 F K16 200 to 1372 C KB7 328 to 2501 F K09 0 0 to 400 0 C KC2 32 0 to 752 0 F K35 200 0 to 400 0 C KC1 328 0 to 752 0 F J J02 0 to 400 C J...

Страница 3: ...idly NS or NET Network status Network is operating normally but communications have not yet been established A green lamp flashes Network is operating normally communications established A green lamp...

Страница 4: ...ommunication mode selection OFF DeviceNet communication mode ON Host communication RS 485 mode Factory set value DeviceNet communication mode Switch No 3 OFF fixed Don t change this one Switch No 8 OF...

Страница 5: ...igure of micro style connector type is the same as a open style connector type Depth in connector mounting Conduct installation in consideration of the sizes of the connector and cable when connector...

Страница 6: ...esistance between the three lead wires To avoid noise induction keep input signal wire away from instrument power line load lines and power lines of other electric equipment If there is electrical noi...

Страница 7: ...Number of inputs 2 points Isolated between each channel Thermocouple input Voltage low input Not isolated between each channel RTD input Voltage high input Current input Input type Thermocouple K J T...

Страница 8: ...nnection T branch connection Terminating resistor 121 1 4 W is necessary Communication speed 125 kbps 250 kbps or 500 kbps Error control CRC error Node address MAC ID duplication check Maximum number...

Отзывы: