Specifications
General Requirements
The installation of any solid fuel heating
appliance is not a do-it-yourself project. The
Energy King should be installed by a
qualified heating specialist. Check with your
fire department and building inspector for
local, state and federal codes regulating
installation. Wood or coal related fires are
caused almost exclusively by installation,
operation or maintenance errors.
Only type HT or Residential type masonry
chimneys intended for use with your Energy
King should be used.
Do not connect this unit to a chimney flue
serving another appliance.
The Energy King is to be used in conjunction
with a listed gas or oil fired furnace or as a
central furnace.
Electrical supply:
115 volts, 60HZ, 1 phase, 15 amps.
Install system with 0.2 static pressure.
Flue setting .06 in of W.C. minimum.
Smoke detectors in “working” condition
should be a part of every Energy King
furnace installation. This is the most
inexpensive insurance you can buy.
Placement – Minimum Clearances
The furnace must be installed on a non-
combustible floor or 3/8 inch thick fireproof
millboard or equivalent. The non-combustible
material must extend at least 8 inches from
the sides and rear of the unit and 24 inches
in front of the unit.
One very important step in positioning your
wood/coal furnace is the distance from your
new or existing chimney. The unit should be
installed as close to the chimney as possible
with a minimum of elbows (no more than two)
and a run of no more than 6 feet horizontally
maintaining a ½ inch rise per linear foot.
Model Number
480EK
360EK
H x W x D
51.5
″
x 26
″
x 60
″
48
″
x 26
″
x 53
″
Shipping Weight (approx.)
650 lbs.
530 lbs.
BTU Capacity (approx.)
160,000
125,000
Blower Capacity
3 Speed
1400-1600-1850
1400-1600-1850
Log Length
26
″
21
″
Coal Capacity
190 lbs
130 lbs
Fire Chamber Capacity
9 Cu. Ft
6.3 Cu. Ft
Loading Door Size
13.5
″
x 15.5
″
13.5
″
x 15.5
″
Ash Door Size
7.25
″
x 11.5
″
7.25
″
x 11.5
″
Flue Size
6
″
6
″
Flue Collar Height
48.25
″
45
″
Plenum Outlet Size
20
″
x 20
″
18
″
x 18
″
Efficiency (approx.)
78%
69%
Leg Height
3.5
″
3.5
″
Combustion Air Diverter
Wood or Coal
Standard
Standard
Filter Box Left or Right Inlet
Optional
Optional
Draft Controls
Forced Draft Thermostatically Controlled
Automatic Draft Thermostatically Controlled
Manual Draft Control
Choice
Choice
N/A
N/A
Optional
Standard
Secondary Heat Exchanger
Standard
Standard
Insulated Cabinet
Standard
Standard
Shaker Grates
Optional
Optional
Wood Grates
Standard
Standard
Cast Iron Hearth Plates
Front and Rear
Standard Standard
Prewired Electrical Components
Standard
Standard
Double Wall Back
Standard
No
Removable Ash Pan
Standard
Standard
Warranty
6 Year Prorated
6 Year Prorated
Complies with
Test Standards
UL391 UL391
Installation
3
Содержание ENERGY KING 360EK
Страница 11: ...Wiring Diagram Auto Draft 8...
Страница 12: ...9 9...
Страница 13: ...Wiring Diagram Manual Draft 10...