AUTION
P
LEASE HEED THE FOLLOWING CAUTIONS
WHEN OPERATING YOUR
E
NERGY
K
ING
FURNACE
:
♦
N
EVER STAND IN FRONT OF THE LOADING
DOOR WHEN OPENING IT
.
S
TAND TO THE
SIDE OF THE DOOR
.
♦
N
EVER
O
PERATE THE UNIT WITH THE ASH
DOOR OPEN
.
♦
U
SE CAUTION WHEN OPENING THE
LOADING DOOR
.
A
VOID OPENING THE
LOADING DOOR RAPIDLY AS THIS CAN
CAUSE A FLAME TO FLASH OUT THE DOOR
.
T
HIS OCCURS WHEN THERE IS UNBURNT
FUEL AND A LARGE AMOUNT OF GASES ON
TOP OF THE FIREBOX
.
W
HEN THE DOOR IS
OPENED RAPIDLY
,
OXYGEN COMBINES
WITH THE GASES AND IGNITES
.
I
MPORTANT
I
N THE EVENT OF A POWER FAILURE
–
1. C
LOSE DRAFT DIAL ON ASH DOOR
.
2. R
EMOVE AIR FILTER
(
IF APPLICABLE
)
.
3. O
PEN ALL HEAT REGISTERS
4. O
NLY LOAD THE UNIT HALF FULL
.
5. K
EEP BYPASS DAMPER CLOSED
.
General Instructions
Please read the following before firing your
furnace. It is very important that you follow
these suggestions and limitations in order to
maintain your warranty and to guarantee the
long life of your furnace.
This furnace is an airtight unit designed to
burn 6 to 8 hours per load of wood or coal. If
the furnace is being fired hot constantly with
full flames and operating at only a 2 to 4 hour
burn cycle,
it is being overfired.
Your home
heating needs may be too great for the size
of furnace you have purchased.
Sometimes you need to allow your existing
furnace to assist you in colder weather. Your
automobile engine works effectively at 55
mph, but can be damaged or destroyed at
constant speeds of 90 mph. Your furnace
can be damaged if it is constantly fired at
extremely high temperatures. Forced firing or
abuse can be detected upon inspection,
and
will void your warranty.
Check Blower Operation.
Check to make
sure that your main blowers, or blower and
draft blower, are in proper working order
before lighting a fire.
♦
To check the main blowers, use the
manual switch on the fan limit control.
♦
To ensure the draft blower is working
properly, turn the thermostat upstairs to a
high temperature to turn the draft blower
on. Check to make sure your draft blower
is working and then set the thermostat to
the desired setting.
First Fire.
The first fire in your Energy King
should be a small one. The unit may smoke
for a few minutes and there may be an odor
during the first firing as the paint and new
steel cure. Do not fully load your furnace or
open all draft controls completely until you
become familiar with the operation of your
furnace.
Manual Draft.
The manual draft controls the
burn rate of your Energy King furnace. When
the manual draft is turned to the left, it will
burn at a higher rate. Turning the dial to the
right sets the burn rate to a slower burn. The
draft dial can be set to any position between
high and low to achieve the desired rate of
burn for your home. The chimney, hookups
and kind of wood used will also be factors in
determining the proper setting for your home.