background image

Energy King Wood/Coal Furnaces

 

Installation and Operating Instructions 

Models 480EK and 360EK 

 
 
 
 
 
 

B

EFORE INSTALLING YOUR 

E

NERGY 

K

ING 

F

URNACE

,

 PLEASE READ ALL OF THE OWNER

MANUAL AND SAFETY NOTES

.

 

P

LEASE SAVE THIS 

MANUAL FOR FUTURE REFERENCE

 
 
 
 
 
 
 

Congratulations on your purchase of an Energy King solid fuel heating appliance. Your Furnace is 
designed for a lifetime of durable, reliable performance and easy operation. This manual describes 
the installation, operation and maintenance of your Energy King Wood or Coal Furnace. 
 
Energy King’s Furnace has been designed to use independently or as an add-on to an existing 
heating system. The installation of any furnace 

is not

 a do-it-yourself project. To ensure the Furnace 

will operate safely and efficiently, the 

installation must be performed by a qualified installer.

 With 

proper installation and maintenance, your Furnace will give you years of trouble free service. Energy 
King’s Furnace is designed to burn Air-Dried Hardwood, Anthracite or Bituminous Coal. 
 
If your Furnace is not properly installed, a house fire may result. For your safety, follow the 
manufacturer’s installation instructions. This Furnace maintains high temperatures when in use. Keep 
combustible materials – such as clothing, paper, and furnishings – clear of the Furnace. Warn 
children of the Furnace’s high temperature. 
 
This Furnace is in compliance with UL 391 test standards. 
 
Prior to installation, inspect your chimney to ensure it is in good condition and free of cracks. Contact 
local building and fire officials regarding restrictions and installation inspection requirements for your 
area. You also need to determine if you are required to obtain a permit from your local governing 
authority. 

Содержание ENERGY KING 360EK

Страница 1: ...Wood or Coal Furnaces Models 360EK and 480EK Installation Operation Maintenance Manual RJM Manufacturing Inc PO Box 27 1875 Olson Drive Chippewa Falls WI 54729 715 720 1794 Fax 715 720 1797...

Страница 2: ...he installation must be performed by a qualified installer With proper installation and maintenance your Furnace will give you years of trouble free service Energy King s Furnace is designed to burn A...

Страница 3: ...ng Diagram Forced Draft 9 Wiring Diagram Manual Draft 10 Filter Box Assembly Schematic 11 STOVEPIPE INSTALLATION 12 BAROMETRIC DRAFT INSTALLATION 12 AIR DUCT INSTALLATION 12 OPERATION 13 GENERAL INSTR...

Страница 4: ...ill cause safety and operation problems 8 Do not connect your solid fuel appliance to a chimney flue already venting another appliance 9 Do not let an accumulation of either soot or creosote build up...

Страница 5: ...022 98 Cast Iron Hearth End Plates 2 EK007 98 Ash Pan removable EK023 98 Shroud Top EK008 98 Self Tapping Bolts 3 EK024 98 Shroud Left Side EK009 98 x Bolts 8 EK025 98 Shroud Right Side EK010 98 Nuts...

Страница 6: ...ant step in positioning your wood coal furnace is the distance from your new or existing chimney The unit should be installed as close to the chimney as possible with a minimum of elbows no more than...

Страница 7: ...is added A common mistake is to assume that sheet metal masonry or asbestos board placed directly against a wall protects it Materials installed in this manner give very little protection These materi...

Страница 8: ...it and the supplemental unit must be compatible If all these conditions are met then the combined static pressure may not exceed that established by the existing furnace Once it has been determined th...

Страница 9: ...mn All chimney connections must meet the approval of the local building inspector and fire marshall and conform to all local state and national codes It is also necessary to clean your chimney of creo...

Страница 10: ...nters past any stops on the dial even though the dial may be graduated beyond the stops Limit Move the right hand pointer so that its straight edge indicates the temperature at which the contacts shou...

Страница 11: ...Wiring Diagram Auto Draft 8...

Страница 12: ...9 9...

Страница 13: ...Wiring Diagram Manual Draft 10...

Страница 14: ...Filter Box Assembly Schematic CAUTION THE FILTER MUST BE REMOVED IF THE FAN IS INOPERABLE FOR ANY REASON THIS WILL PREVENT OVERHEATING OF THE MOTOR THE AIR FILTER MUST BE NON COMBUSTIBLE 11...

Страница 15: ...n Dampers in Stovepipes Put a manual damper at a safe convenient place between the chimney and your Energy King furnace In case of a chimney fire it can quickly be closed reducing draft to the chimney...

Страница 16: ...weather Your automobile engine works effectively at 55 mph but can be damaged or destroyed at constant speeds of 90 mph Your furnace can be damaged if it is constantly fired at extremely high tempera...

Страница 17: ...couple of handfuls of dry thick kindling wood then several small pieces of firewood Be sure the bypass damper is open 3 It will take 5 to 10 minutes for the fire to establish itself Once you have som...

Страница 18: ...build up the coal bed 5 Allow your Energy King to operate with drafts on for approximately 15 minutes or until fresh coal ignites When the coal is properly ignited adjust the thermostat accordingly 6...

Страница 19: ...ntly creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot hot fire The chimney connector and chimney should be inspected at least twice monthly during the...

Страница 20: ...eaks Door gaskets glass gaskets ash drawer or door gaskets where applicable Unit does not give off enough heat Is the unit installed correctly 1 Check to see if the unit has an adequate cold air retur...

Страница 21: ...n cause creosote buildup in smoke pipe and chimney Coal fire goes out or does not hold overnight Check for the following conditions 1 Poor draft 2 Incorrect damper settings 3 Improper firing methods f...

Страница 22: ...ter preheating the chimney If hardwoods are unavailable you can control your fire s burn rate by using larger pieces of wood Q Is it important to season wood before burning it R The seasoning or dryin...

Страница 23: ...hase All transportation charges on warranty appliances and appliance parts submitted for repair or replacement under this warranty shall be paid for the by purchaser field analysis of condition remova...