background image

Product Manual | Lynx™ Shielded Analog Input Module IA1‑M‑V

RJG, Inc.

13

RELATED PRODUCTS

The shielded analog input module is compatible 
with other RJG, Inc. products for use with the 

eDART

 process control and monitoring system.

COMPATIBLE PRODUCTS

SHIELDED ANALOG INPUT MODULE CABLE 

C‑IA1‑M‑3M

The shielded analog input module cable 
C‑IA1‑M‑3M (

1

 at right

) cable features a metal 

sheathing  and shielding suited for the heat and 
stress found in injection molding environments. 
Designed specifically for use with RJG, Inc.’s 
analog input module IA1‑M‑V and the e

DART

 

System, the C‑IA1‑M‑3M provides a connection 
from molding machines’ output card and the RJG, 
Inc. C‑IA1‑M‑3M. 

LYNX SHIELDED SEQUENCE MODULE 

ID7‑M‑SEQ

The Lynx shielded sequence module 
ID7‑M‑SEQ (

2

 at right

) is a DIN‑rail‑mounted 

module that is wired to the molding machine 
in order to collect 24 V DC timing signals for 
use with the 

eDART

 

system, including injection 

forward, screw run, mold closed, first stage, 
and mold opening. 

eDART

 PROCESS CONTROLLER

The 

eDART

 process controller (

3

 at right

) is 

the base hardware unit for the 

eDART

 system. 

The 

eDART

 system is the most powerful process 

control system in the industry, allowing molders 
to stabilize and control injection molding 
processes and contain bad parts, ensuring high 
quality and cost‑reduction.    

1

2

3

Содержание Lynx IA1-M-V

Страница 1: ...PRODUCT MANUAL Training and Technology for Injection Molding Lynx Shielded Analog Input Module IA1 M V...

Страница 2: ...PRINT DATE 02 25 2019 REVISION NO 0...

Страница 3: ...S 1 PROCESS MONITORING AND CONTROL 1 OPERATION 1 INJECTION PRESSURE 1 SCREW POSITION VELOCITY 1 DEW POINT 1 OTHER SUPPORTED SENSOR TYPES 2 DIMENSIONS 3 CABLE LENGTH 3 INSTALLATION INSTALLATION OVERVIE...

Страница 4: ...RT ON PRESS POWER UP 11 INCORRECT INJECTION PRESSURE SCALING 11 CUSTOMER SUPPORT 12 RELATED PRODUCTS COMPATIBLE PRODUCTS 13 SHIELDED ANALOG INPUT MODULE CABLE C IA1 M 3M 13 LYNX SHIELDED SEQUENCE MODU...

Страница 5: ...ed uses of the material or designs described herein are not to be construed as constituting a license under any RJG Inc patent covering such use or as recommendations for use of such material or desig...

Страница 6: ...Lynx Shielded Analog Input Module IA1 M V Product Manual iv RJG Inc...

Страница 7: ...ne temperature melt pressure mold deflection mold temperature power consumption revolution rate and vacuum INJECTION PRESSURE The IA1 M V is often used to acquire an injection pressure signal from ele...

Страница 8: ...also supports the additional following sensor types Ejector Pin indirect Hydraulic Pressure Mold Temperature Barrel Temperature Coolant Temperature Coolant Flow Rate Delta Pressure Revolution Rate OPE...

Страница 9: ...Product Manual Lynx Shielded Analog Input Module IA1 M V RJG Inc 3 DIMENSIONS CABLE LENGTH CABLE LENGTH The C IA1 M 3M is 9 8 ft 3 m long...

Страница 10: ...Lynx Shielded Analog Input Module IA1 M V Product Manual 4 RJG Inc...

Страница 11: ...output card on one end or to some other 0 10 V measurement device and connected to the IA1 M V on the other using the four pin connector The shielded analog input module is connected to the ID7 M SEQ...

Страница 12: ...ust be located away from any static sources such as feeder tubes and material hoppers WIRING The C IA1 M 3M cable has colored coded wires to simplify installation Refer to the table below for the corr...

Страница 13: ...ould be displayed in the Value column Record the machine value for the measurement at this time as well For example if using the IA1 M V to acquire injection pressure from the machine record the machi...

Страница 14: ...er 5 Enter the machine value recorded in step 4 into the Maximum field and select the appropriate units of measurement 6 Enter the maximum voltage recorded in step 4 into the Voltage at Maximum Pressu...

Страница 15: ...and robustness of the shielded analog input module and so are offering a one year warranty RJG s products are guaranteed against defects in material and workmanship for one year from the original dat...

Страница 16: ...Lynx Shielded Analog Input Module IA1 M V Product Manual 10 RJG Inc...

Страница 17: ...s started before machine is powered on Solution Always power the eDART on after the machine is powered on Analog signals tend have a spike or a sudden lurch from zero to a specific position voltage Of...

Страница 18: ...Analog Input Module IA1 M V Product Manual 12 RJG Inc CUSTOMER SUPPORT Contact RJG s Customer Support team by phone or email RJG Inc Customer Support P 800 472 0566 Toll Free P 1 231 933 8170 www rjgi...

Страница 19: ...ART System the C IA1 M 3M provides a connection from molding machines output card and the RJG Inc C IA1 M 3M LYNX SHIELDED SEQUENCE MODULE ID7 M SEQ The Lynx shielded sequence module ID7 M SEQ 2 at ri...

Страница 20: ...YNX SHIELDED DUAL RELAY OUTPUT MODULE OR2 M The Lynx shielded dual relay output module OR2 M 2 at right is a shielded DIN rail mounted module that interfaces the eDART and sorting equipment or injecti...

Страница 21: ......

Страница 22: ...E A PTE LTD Singapore Republic of Singapore P 65 6846 1518 sales swg rjginc com en rjginc com FRANCE RJG FRANCE Arnithod France P 33 384 442 992 sales fr rjginc com fr rjginc com CHINA RJG CHINA Chen...

Отзывы: