background image

Product Manual | Lynx™ Shielded Analog Input Module IA1‑M‑V

RJG, Inc.

9

MAINTENANCE

The shielded analog input module requires little 
to no maintenance provided that all installation 
instructions are followed. 

CLEANING 

REGULAR CLEANING

Cables must be installed in areas free from oil, 
dirt, grime, and grease.

RJG, Inc. recommends the following cleaners:

• 

Microcare MCC‑CCC Contact Cleaner C

• 

Microcare MCC‑SPR SuprClean™

• 

Miller‑Stephenson MS‑730L Contact Re‑Nu

®

WARRANTY

RJG, INC. STANDARD WARRANTY

RJG, Inc. is confident in the quality and 
robustness of the shielded analog input module, 
and so are offering a one‑year warranty. RJG’s 
products are guaranteed against defects in 
material and workmanship for one year from 
the original date of purchase. The warranty is 
void if it is determined that the adapter was 
subjected to abuse or neglect beyond the 
normal wear and tear of field use, or in the 
event the adapter box has been opened by the 
customer.

PRODUCT DISCLAIMER

RJG, Inc. is not responsible for the improper 
installation of this equipment, or any other 
equipment RJG manufactures.

Proper RJG equipment installation does not 
interfere with original equipment safety features 
of the machine. Safety mechanisms on all 
machines should never be removed.

Содержание Lynx IA1-M-V

Страница 1: ...PRODUCT MANUAL Training and Technology for Injection Molding Lynx Shielded Analog Input Module IA1 M V...

Страница 2: ...PRINT DATE 02 25 2019 REVISION NO 0...

Страница 3: ...S 1 PROCESS MONITORING AND CONTROL 1 OPERATION 1 INJECTION PRESSURE 1 SCREW POSITION VELOCITY 1 DEW POINT 1 OTHER SUPPORTED SENSOR TYPES 2 DIMENSIONS 3 CABLE LENGTH 3 INSTALLATION INSTALLATION OVERVIE...

Страница 4: ...RT ON PRESS POWER UP 11 INCORRECT INJECTION PRESSURE SCALING 11 CUSTOMER SUPPORT 12 RELATED PRODUCTS COMPATIBLE PRODUCTS 13 SHIELDED ANALOG INPUT MODULE CABLE C IA1 M 3M 13 LYNX SHIELDED SEQUENCE MODU...

Страница 5: ...ed uses of the material or designs described herein are not to be construed as constituting a license under any RJG Inc patent covering such use or as recommendations for use of such material or desig...

Страница 6: ...Lynx Shielded Analog Input Module IA1 M V Product Manual iv RJG Inc...

Страница 7: ...ne temperature melt pressure mold deflection mold temperature power consumption revolution rate and vacuum INJECTION PRESSURE The IA1 M V is often used to acquire an injection pressure signal from ele...

Страница 8: ...also supports the additional following sensor types Ejector Pin indirect Hydraulic Pressure Mold Temperature Barrel Temperature Coolant Temperature Coolant Flow Rate Delta Pressure Revolution Rate OPE...

Страница 9: ...Product Manual Lynx Shielded Analog Input Module IA1 M V RJG Inc 3 DIMENSIONS CABLE LENGTH CABLE LENGTH The C IA1 M 3M is 9 8 ft 3 m long...

Страница 10: ...Lynx Shielded Analog Input Module IA1 M V Product Manual 4 RJG Inc...

Страница 11: ...output card on one end or to some other 0 10 V measurement device and connected to the IA1 M V on the other using the four pin connector The shielded analog input module is connected to the ID7 M SEQ...

Страница 12: ...ust be located away from any static sources such as feeder tubes and material hoppers WIRING The C IA1 M 3M cable has colored coded wires to simplify installation Refer to the table below for the corr...

Страница 13: ...ould be displayed in the Value column Record the machine value for the measurement at this time as well For example if using the IA1 M V to acquire injection pressure from the machine record the machi...

Страница 14: ...er 5 Enter the machine value recorded in step 4 into the Maximum field and select the appropriate units of measurement 6 Enter the maximum voltage recorded in step 4 into the Voltage at Maximum Pressu...

Страница 15: ...and robustness of the shielded analog input module and so are offering a one year warranty RJG s products are guaranteed against defects in material and workmanship for one year from the original dat...

Страница 16: ...Lynx Shielded Analog Input Module IA1 M V Product Manual 10 RJG Inc...

Страница 17: ...s started before machine is powered on Solution Always power the eDART on after the machine is powered on Analog signals tend have a spike or a sudden lurch from zero to a specific position voltage Of...

Страница 18: ...Analog Input Module IA1 M V Product Manual 12 RJG Inc CUSTOMER SUPPORT Contact RJG s Customer Support team by phone or email RJG Inc Customer Support P 800 472 0566 Toll Free P 1 231 933 8170 www rjgi...

Страница 19: ...ART System the C IA1 M 3M provides a connection from molding machines output card and the RJG Inc C IA1 M 3M LYNX SHIELDED SEQUENCE MODULE ID7 M SEQ The Lynx shielded sequence module ID7 M SEQ 2 at ri...

Страница 20: ...YNX SHIELDED DUAL RELAY OUTPUT MODULE OR2 M The Lynx shielded dual relay output module OR2 M 2 at right is a shielded DIN rail mounted module that interfaces the eDART and sorting equipment or injecti...

Страница 21: ......

Страница 22: ...E A PTE LTD Singapore Republic of Singapore P 65 6846 1518 sales swg rjginc com en rjginc com FRANCE RJG FRANCE Arnithod France P 33 384 442 992 sales fr rjginc com fr rjginc com CHINA RJG CHINA Chen...

Отзывы: