ENGLISH
68
Picture 7 - Cooker with oven multiflue, predisposition of the correct flue outlet
ZV 90
2.9
CORRECT CONJUNCTION TO THE CHIMNEY
If the conduct of the chimney starts from
a lower floor than the connection point of
the cooker, it may be necessary to close the
conduct under the connection pipe with
fireproof materials.
If you have the chimney behind or up, you
have to use the connector with bayonet cou-
pling. This must be inserted and turned so
that it can remain blocked. This connector
has a tolerance of about 1 cm to make the
installation easier. The tolerance is available
according to a single direction which de-
pends on the orientation of the connector
(see picture 8).
Picture 8 - Tolerance for flue outlet on the top and back. The tolerance depends on the orientation of the connector.
+/-
10 mm
Y
X
+/-
10 mm
The connection with the chimney must be
always well fixed and sealed, it must not
have narrowing and must not decrease the
usable section of the chimney (see picture
10). If near the cooker there is inflammable
material or high temperatures sensible, the
connection must be isolated and the safety
distances must be strictly observed.