![Riwall PRO RET 3275 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/riwall-pro/ret-3275/ret-3275_translation-of-original-instructions_1466263057.webp)
service agent or similarly qualified persons in order to avoid a hazard.
The mains voltage must correspond to the one marked on the techN1Cal
data plate (230V~50Hz). Do not use other sources of power.
The use of a safety circuit-breaker is recommended for the power supply
line for an intervention range of 10 to 30mA. Consult a reliable electrician.
Never pass the appliance over the extension cable that the application is
working, as this could cut the cable. Mark sure you always know where the
cable is.
Use the special cable holder for the connection of the extension cable.
Never use the appliance when it is raining. Try to prevent it from getting wet
or being exposed to humidity. Do not leave it outside overnight. Do not cut
damp or wet grass.
The power supply cable should be checked regularly and before using it
each time, make sure the cable is not damaged or old out. If the cable is
not in good condition, do not use the appliance; take it to an authorized
service center instead.
Only use an extension cable that is suitable for outdoor work. Keep it away
from the cutting area, from damp, wet or oily surfaces or with sharp edges
and away from heat and fuels.
The mobile socket of the extension cable should be in compliance with
related regulations; Use harmonized rubber cable (H07RN-F) with at least
1.5 mm2 cross-section and sufficient length.
INTENDED USE
This device is intended for use with an electric cultivator - only for
crushing lumps of digged flower beds - and only on private land and
gardens. Not intended for plowing.
It is not designed for use in public areas, parks, sports areas, and in agriculture
and forestry.
Using the application for any other purpose is considered incorrect and
unapproved. The manufacturer is not liable for any damage or injury resulting
from such use. The user is entirely responsible for any associated risks.
Double insulation
The electric tiller has double insulation. This means that all external metal parts
are insulated from the electrical supply.
This is achieved by introducing insulation layer between electrical and
mechanical parts. The double insulation guarantees you the greatest possible
safety.
Overheat protection
If the application is blocked by a foreign object or if the motor is overloaded,
the motor will switch off automatically by the protection device. Release the
trigger level and wait till the motor cool down (approx. 15 minutes) then start
application again.
LIST OF MAIN PARTS