34
SteelConnect SDI-5030 Gateway Hardware Installation Guide
Replacing SteelConnect Gateway SDI-5030 Components
Replacing fans
Replacing fans
This section describes how to replace fans in the gateway. The gateways are equipped with six fans that
are not hot swappable. You must power down the gateway before replacing the fans.
Note:
You must use approved fans. To order fans, contact Riverbed Support at https://support.riverbed.com.
To replace a fan
1.
Power off the gateway and remove the chassis cover.
See
“Removing and installing the chassis cover” on page 25
.
2.
Identify the faulty fan. Disconnect the fan cable from the cable jack on the motherboard and remove
the faulty fan from the dock.
Figure 3-15. Fan numbering
3.
Lift the fan assembly from the chassis and push out the faulty fan.
Figure 3-16. Removing the fan assembly
4.
Install the replacement fan into the fan assembly, ensuring all the rubber guides are in place and the
cable is located on the side closest to the server board.