SteelConnect SDI-5030 Gateway Hardware Installation Guide
31
Replacing memory modules
Replacing SteelConnect Gateway SDI-5030 Components
To replace a memory module in the gateway
1.
Power down the gateway.
2.
Remove the chassis cover.
See
“Removing and installing the chassis cover” on page 25
.
3.
Remove the air duct.
See
“Removing and installing the air duct” on page 27
.
4.
Press the ejector tabs on the memory slots down and outward, and gently pull the memory module
out of the slot.
5.
Replace the memory module with an approved memory module of the same size.
Note:
Replacing the existing memory module with a module of a different size causes the gateway to fail. You must
use approved memory modules. Contact Riverbed Support at https://support.riverbed.com to obtain the correct
memory modules.
6.
Align the memory-module edge connector with the slot alignment keys and insert it into the slot.
The module slot has two alignment keys that allow you to install the module in only one direction.
Figure 3-12. Inserting the memory modules into the connector slot and securing
7.
Press down on the memory module with your thumbs while pulling up on the ejectors with your index
fingers to lock the module into the slot.
8.
Ensure that all ejector tabs are in the upright locked position.
9.
Replace the chassis cover.
10.
Replace the power cords and peripherals.
11.
Power on the gateway.