EN
Multiprocess 175. Operating manual.
Multiprocess 175. Operating manual.
25
24
Installation for TIG process
7.2 Installation for TIG process
1. Connect the gas cylinder to the regulator.
3
Select correct shielding
gas for the application.
2. Connect the dinse plug of the TIG torch
2
to negative (–) on the front
panel
5
, and fasten it clockwise.
3. Connect the electrical lead of the TIG torch
2
to the relative interfaces
of the panel and fasten the screw.
4. Connect one end of the work return lead to positive (+)
4
on the front
panel, and fasten it clockwise. Connect the other end of the clamp
1
to the workpiece.
Installation for MMA process
7.3 Installation for MMA process
1. Connect the electrode holder
1
to the positive (+)
4
on the machine
and fasten it clockwise tightly.
2. Connect the work return lead
3
into the negative (–)
3
on the
machine and fasten it clockwise.
Please note
that for manual metal arc (MMA) welding the electrode
holder can be switched to the negative pole of the welding machine if
so required by the specification of the electrode.
8. Control panel.
Front panel of Multiprocess 175
1
Multifunctional data display,
2
MMA/LIFT TIG/MIG,
3
Wire speed,
4
VRD/2T/4T switch,
5
Data selection,
6
Multifunctional data adjustment
3
5
6
2
1
4