![RITE-HITE BARRIER GLIDER 7100 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/rite-hite/barrier-glider-7100/barrier-glider-7100_manual_1464542006.webp)
BARRIER
®
GLIDER Single Slide Model 7100
6
PUB. NO. 7100SSG FEBRUARY 2008
NOTE:
Figure 3
is for doors that the motor is mounted on
the jamb side,
Figure 3A
is for doors that the
motor is mounted on the storage side.
1.
Position Thermal Air Sealing system in front of the
opening.
2.
Place marks on top of the jamb at O.D.H. plus 5 3/8”.
3.
Place marks at 1/2 D.O.W. plus 5 3/8” on the storage side
of the jamb,
Figure 3 or 3A.
4.
Place the outside of the perimeter seal retainers to the
wall on these marks and fasten every 18” using the
#14 x 1 1/4" hex head screws provided.
5.
Make sure the top is centered and corners are not
binding.
6.
Make sure vertical part of seal touches the floor on both
sides.
7.
Mount the blower to the wall, so the vertical section will
attach to it, the fabric should be taught but not stretched
when clamping to the blower,
Figure 3 or 3A.
Use (4)
#14 x 1 1/4" hex head screws.
8.
Fasten the retainer and the white rope of the seal to the
wall at the bottom, pull tight and fasten at the top to avoid
twisting or wrinkling of the bag,
Figure 4.
9.
After seal installation caulk the entire inside perimeter of
the aluminum retainer. Failure to do this may result in
frost or ice buildup.
PERIMETER SEAL INSTALLATION
FIGURE 3- JAMB SIDE DRIVE
Vertical Extension
Fastened to Blower
BOTH SIDES:
Air Outlet Hole
MUST Not Be
Obstructed.
Pull Seal Taught
and Tight to the
Floor and
Screw Retainer
to Hold in Place
D.O.W.
1/2 D.O.W.
O.D.H. + 5 3/8”
DOOR OPENING
L
C
Make sure that the bag is not twisted when installing.
Periodic cleaning of the perimeter air bag sealing
system may be required.
I M P O R TA N T ! ! !
5 3/8”
Retainer
Seal
Optional
Blockout
Screw Retainer to the
Wall After Fastening
at the Bottom
FIGURE 4
Air Bag
Seal
Exhaust Hole
w/ Grommet
Fasten Thru
Retainer and
Seal Rope
D.O.W. + 5 3/8”
Storage Side
Thermal Air
®
Sealing
System. Fasten Seal
Retainer Every 18”
FIGURE 3A- STORAGE SIDE DRIVE
Vertical Extension
to Blower
BOTH SIDES:
Air Outlet Hole
MUST Not Be
Obstructed.
Pull Seal Taught
and Tight to the
Floor and
Screw Retainer
to Hold in Place
D.O.W.
1/2 D.O.W.
O.D.H. + 5 3/8”
DOOR OPENING
L
C
5 3/8”
Retainer
Seal
Optional
Blockout
Screw Retainer
to the Wall
After Fastening
at the Bottom
D.O.W. + 5 3/8”
Storage Side
Thermal Air
®
Sealing
System. Fasten Seal
Retainer Every 18”