TROUBLESHOOTING INFORMATION 

  Problem 

         Possible Causes                   Solution 

R100 compressor 
and fan will not start 

 

 

 

 

 

 

 

R100 compressor will 
not start but fan runs 

 

 

 

 

 

R100 starts but stops 
after a short period 

 

 

R100 trips circuit 
breaker upon start up 

 

 

 

R100 will not perform 
liquid push-pull   
recovery 

Power cord not plugged in 

Socket not energized 

High Pressure Switch       
activated 

 

Tank Overfill Sensor activated 

Circuit Breaker is tripped 

Defective system switch 

Broken or loose wire 

Compressor Start relay or 

capacitor defective 

Compressor thermal overload 
is tripped 

Compressor leads are broken 
or loose 

 

Restriction in the discharge 

line tripping the high pressure 

switch 

 

High differential pressure 

across compressor suction 

and discharge valves 

 

System to be serviced does 

not allow liquid recovery 

 



Plug in to energized socket 



Check socket for power 



Check for restrictions 



Check recovery tank 



Turn off power to reset 



Reset circuit breaker 



Replace switch 



Repair electrical connection 



Replace the relay or capacitor 

 



Thermal overload will automati-

cally reset 



Repair compressor leads 

 



Open valve on recovery tank 



Check for other restrictions 



Turn off power to reset 

 



Turn Discharge Valve to the 
PURGE position for 5 seconds.  
Return valve back to          
RECOVERY position. 

 



Use Direct Recovery method 

TECHNICAL SUPPORT:  800-769-8370  



Call this number if you require additional information on your YELLOW JACKET

®  

Unit. 

 

FOR WARRANTY OR OTHER SERVICE: 



Contact your YELLOW JACKET

®

 Distributor 

Содержание YELLOW JACKET R100

Страница 1: ...1 R100 Oil Less Refrigerant Recovery Unit Operation Manual...

Страница 2: ...epth 13 25 in Weight 48 lb Welcome to simple efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit R100 This unit combines the latest oil less compressor technology with...

Страница 3: ...isconnect Unit from Power Supply Before Servicing An electrical shock hazard is present when the unit is disas sembled Repair Damaged Parts Do not operate the unit with a defective part Repair unit to...

Страница 4: ...r 40 CFR part 82 subpart F or current equivalent Before operating this unit please read this manual thoroughly You must understand the procedures outlined in this manual Failure to follow these proced...

Страница 5: ...system does not allow for a solid column of liquid refrigerant to be formed When using push pull recovery the R100 will not recover to the required vacuum level in the recovered system Use a sight gla...

Страница 6: ...igh pressure limit Turn off power and check for restrictions If tank pressure is above 400 psig exchange tank Repeat Steps 3 6 7 Turn the Tank Vapor Valve to OFF Wait until suction pressure gauge indi...

Страница 7: ...ry tank as shown in the figure 2 The suction hose can be connected to the liquid and or vapor service ports If you connect to the liquid service port ensure you use Liquid Recovery Also ensure the hos...

Страница 8: ...charge Gauge Indicates the discharge pressure of the recovery unit s condenser 6 Cooling Fan This fan provides airflow through the condenser and across the compressor 7 Suction Valve Valve for selecti...

Страница 9: ...g the high pressure switch High differential pressure across compressor suction and discharge valves System to be serviced does not allow liquid recovery Plug in to energized socket Check socket for p...

Страница 10: ...10 Notes recovery tank hvac unit or appliance recovery tank REPAIR PARTS DIAGRAM...

Страница 11: ...rd 3 Compressor hoses 4 95154 Compressor includes head 5 95251 Suction Valve w Strainer 6 95190 Capacitor 7 95233 Compressor Relay 8 95252 Foam for Handles 9 95213 Low Pressure Gauge 10 95212 High Pre...

Страница 12: ...S A 04 06 FK 150834 Recovery Division 6701 West 110th Street Bloomington MN 55438 USA Phone 952 943 1333 Phone 800 769 8370 Fax 952 943 1605 Fax 800 322 8684 Email custserv yellowjacket com Web www y...

Отзывы: