REPAIR PARTS LIST 

The following list contains the major components of the R100.  To order these parts, 
please contact your YELLOW JACKET

®

 Dealer. 

 
Please have the following information available when you call. 
 
Model:        R100 

Serial Number:     

    Date of Purchase:  

 

Part Number 

Description 

1 95248 

95188 

Tank Overfill Sensor 

Cord Shorting Cap 

2 95215 Power 

Cord 

3  Compressor 

hoses 

4 95154 Compressor 

(includes head) 

95251 

Suction Valve w/

Strainer 

6 95190 Capacitor 

7 95233 Compressor 

Relay 

8 95252 Foam 

for 

Handles 

9 95213 Low 

Pressure 

Gauge 

10 95212 High 

Pressure 

Gauge 

11 95253 PC 

Board 

w/Remote 

LED’s 

 

Part Number 

Description 

12 G-95254 

Y-95255 

R-95256 

Remote LED’s 

13 95173 High 

Pressure 

Switch 

14 95206 Discharge 

Valve 

15 95257 Fan 

16 95241 Guard 

17 95232 Circuit 

Breaker 

18 95216 Rocker 

Switch 

19 95228 Condenser 

20 

95163 

2 psig Check 

Valve 

21 

95247 

10 psig Check 

Valve 

22 95258 Operation 

Manual 

Содержание YELLOW JACKET R100

Страница 1: ...1 R100 Oil Less Refrigerant Recovery Unit Operation Manual...

Страница 2: ...epth 13 25 in Weight 48 lb Welcome to simple efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit R100 This unit combines the latest oil less compressor technology with...

Страница 3: ...isconnect Unit from Power Supply Before Servicing An electrical shock hazard is present when the unit is disas sembled Repair Damaged Parts Do not operate the unit with a defective part Repair unit to...

Страница 4: ...r 40 CFR part 82 subpart F or current equivalent Before operating this unit please read this manual thoroughly You must understand the procedures outlined in this manual Failure to follow these proced...

Страница 5: ...system does not allow for a solid column of liquid refrigerant to be formed When using push pull recovery the R100 will not recover to the required vacuum level in the recovered system Use a sight gla...

Страница 6: ...igh pressure limit Turn off power and check for restrictions If tank pressure is above 400 psig exchange tank Repeat Steps 3 6 7 Turn the Tank Vapor Valve to OFF Wait until suction pressure gauge indi...

Страница 7: ...ry tank as shown in the figure 2 The suction hose can be connected to the liquid and or vapor service ports If you connect to the liquid service port ensure you use Liquid Recovery Also ensure the hos...

Страница 8: ...charge Gauge Indicates the discharge pressure of the recovery unit s condenser 6 Cooling Fan This fan provides airflow through the condenser and across the compressor 7 Suction Valve Valve for selecti...

Страница 9: ...g the high pressure switch High differential pressure across compressor suction and discharge valves System to be serviced does not allow liquid recovery Plug in to energized socket Check socket for p...

Страница 10: ...10 Notes recovery tank hvac unit or appliance recovery tank REPAIR PARTS DIAGRAM...

Страница 11: ...rd 3 Compressor hoses 4 95154 Compressor includes head 5 95251 Suction Valve w Strainer 6 95190 Capacitor 7 95233 Compressor Relay 8 95252 Foam for Handles 9 95213 Low Pressure Gauge 10 95212 High Pre...

Страница 12: ...S A 04 06 FK 150834 Recovery Division 6701 West 110th Street Bloomington MN 55438 USA Phone 952 943 1333 Phone 800 769 8370 Fax 952 943 1605 Fax 800 322 8684 Email custserv yellowjacket com Web www y...

Отзывы: