background image

Before You Start 
Contac

ti

ng Ritchie 

To order accessories, receive assistance, or 
locate the nearest YELLOW JACKET distributor. 

Safety Informa

ti

on 

Use the instrument only as speci

ed in this 

manual. Otherwise, the protec

ti

on provided by 

the instrument may be impaired. Refer to the 
safety informa

ti

on.  

A Warning iden

tifi

es condi

ti

ons and ac

ti

ons 

that pose hazards to the user. A Cau

ti

on 

iden

tifi

es condi

ti

ons and ac

tio

ns that may 

damage the instrument or the equipment 
under test. 

Warning 

To avoid personal injury or death, follow these 
guidelines: 

 

Most governments and legal authori

tie

require that HVAC technicians be 
trained and cer

tifi

ed in the safe and 

proper opera

ti

on of HVAC tools, such as 

this instrument. Since this tool may be 
connected to many types of equipment 
through a limitless combina

ti

on of hoses 

and 

fitti

ngs, proper training is the most 

important element of using this tool 
safely. 

 

Read the en

tire

 Users Manual before 

using the instrument. 
Use the instrument only as described in 

this Users Manual, otherwise the 
protec

ti

on provided by the equipment 

may be impaired.  

 

Do not use the instrument if it is 
damaged. Before you use the 
instrument, inspect the case. Look for 
cracks or loose components. 

 

The instrument contains no internal 
user serviceable parts  
Do not open the instrument. 
 Have the instrument serviced only by 
Ritchie Engineering Co. or authorized 
service centers. 

 

Do not use the instrument if it operates 
abnormally. Protec

ti

on may be 

impaired. When in doubt, have the 
instrument serviced. 

 

Do not operate the instrument around 
explosive gas, vapor, or dust. 

 

Various refrigerants have been 
inten

ti

onally excluded for very 

signi

cant safety reasons.  

 

Never use refrigerants in this 
instrument that are not listed in the Set-
up menu. 
The refrigerant database in this unit 
may include refrigerants classi

fie

d as 

flam

mable. If such refrigerants are 

selected, the operator may need 
addi

tio

nal cer

tifi

ca

ti

ons and/or training. 

Consult your government and legal 
authority and comply fully with all 
requirements. 
Always wear eye and skin protec

tion 

when working with refrigerants. 
Escaping refrigerant vapors will present 
a freezing danger. Do not direct 

2

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Содержание Yellow Jacket ManTooth Series

Страница 1: ...rks of Google Inc The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by Ritchie Engineering is under license Other trademarks and trade names are those of their respective owners Made for iPhone and Made for iPad mean that an electronic accessory has been designed to connect specifically to iPhone or iPad respectively and has been certi...

Страница 2: ...rovided by the equipment may be impaired Do not use the instrument if it is damaged Before you use the instrument inspect the case Look for cracks or loose components The instrument contains no internal user serviceable parts Do not open the instrument Have the instrument serviced only by Ritchie Engineering Co or authorized service centers Do not use the instrument if it operates abnormally Prote...

Страница 3: ...rgers to recharge the ManTooth PT Module as this could damage the circuitry and or battery Only use with refrigerants approved for use with the ManTooth PT Module Use of unapproved refrigerants may cause damage to the ManTooth PT Module A complete list of approved refrigerants can be found in the ManTooth RSA app in the Select Refrigerant option Getting Started The ManTooth PT Module is a precise ...

Страница 4: ...eleasing the power button on the main module If you have a 67002 dual unit the main module is the one that says ManTooth PT Module on the label not the one that says ManTooth PT Tether Module The module will go through a brief start up sequence then the light on your ManTooth PT Module should start to blink blue This means that your ManTooth PT Module is searching for available Bluetooth devices t...

Страница 5: ...various functions settings and procedures of the ManTooth RSA Pressure Temperature App If you have not already downloaded the Yellow Jacket ManTooth RSA Pressure Temperature App go to either the Apple App Store or the Google Play Store now to download the free app You can either use the QR code links that are on your ManTooth PT Module packaging follow the links that are available on YellowJacket ...

Страница 6: ...hat the temperature readings from the temperature sensors Vapor Saturation Liquid Saturation and the values for Superheating and Subcooling are displayed in Options are degrees Fahrenheit F or degrees Celsius C Default temperature units are degrees Fahrenheit F Pressure Preference Set the units that the pressure readings are displayed in Available units are bar pounds per square inch absolute psia...

Страница 7: ... off timer if you wish to reset the timer simply tap anywhere on the screen Also included is an auto off never setting Moving the slider all the way to the left will set the auto off timer to never Default is Auto Off 5 min Getting Back to the Previous Screen To return to the previous screen from the one you are currently viewing tap on the icon in the upper left hand corner This function is the same...

Страница 8: ...r the current session tap on Refrigerant then scroll through the list of almost 100 NIST refrigerants and select the refrigerant corresponding to the unit you will be servicing If you accidently select an incorrect refrigerant do not worry you can also change the refrigerant later in the readings screen Setting a refrigerant is mandatory before moving to the next screen WARNING Refrigerants classi...

Страница 9: ...o Assign Detected Devices Now you are ready to connect your ManTooth PT Module to your current session To connect your module first tap on Devices None Specified this will take you to the next screen Tap on the ManTooth PT Module s that you wish to connect to your session from the list of devices that are displayed Remember your Module s name is the serial number printed on the main label and should...

Страница 10: ...he appropriate time to connect your ManTooth PT Module to your system Connecting the ManTooth PT Module to the system before beginning your session will also ensure that the average minimum and maximum readings are accurate Readings The readings screen will display the pressures and temperatures as measured by the ManTooth PT Module display the liquid and vapor saturation values as well as calcula...

Страница 11: ...based on the measured pressure and the refrigerant selected Temperature To assign temperature readings to either the high or low side simply tap on the box that contains the value you wish to assign and select the sensor that you want to assign to that spot Note the label on the ManTooth PT Module denotes which temperature port is T1 and which is T2 for easy reference Subcooling and Superheat To s...

Страница 12: ...istory section on the app s home screen Any saved service data can be emailed from within Session History Other Buttons At the bottom of the readings screen there are two additional buttons The first is labeled Clear readings This will clear the minimum maximum and average readings of the session This function is especially useful for determining system stability The other option is Exit Session Th...

Страница 13: ...vice Name Your ManTooth PT Module s name is displayed right on the label for easy reference The name takes the form of YJPT XXXX XXXX The device name serves as your ManTooth PT Module s name within the ManTooth RSA app its serial number as well as its Bluetooth name that will appear on your phone or tablet when pairing Temperature Probe Indicator On the label of the ManTooth PT Module T1 and T2 ar...

Страница 14: ...nge instrument Sensing element 40 F to 266 F 40 C to 130 C Max Cord temp 176 F 80 C Max Clamp Temp 203 F 95 C Temperature Display Resolution 0 1 F or C Temperature Accuracy Instrument 0 2 C 0 36 F Working Temperature 4 F to 160 F Limited by battery Storage Temperature 4 F to 160 F For best battery performance do not store at over 100 F Working humidity 0 to 95 RH non condensing IP Class IP 50 Batt...

Страница 15: ...er 50 times more refrigerant with each connection Pressure Zeroing Simple single button zeroing at the start of each session Elevation Compensation Enter elevation at the start of the session for effortless psia compensation Battery Rechargeable LiPo battery for long battery life and excellent recharging capability for the life of your ManTooth 15 ...

Страница 16: ...l other YELLOW JACKET products included in this package are guaranteed to be free from material and workmanship defects for a period of one year These guarantees do not cover prod ucts that have been altered abused misused or improperly maintained 2014 Ritchie Engineering Co Inc 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Отзывы: