Thrifty King fountains are intended to be energy-free; however, a number of factors must be met for this to be the
case:
There must be at least 10 animals that have the Thrifty King fountain as their only source of water.
There must be a good seal against wind between the concrete platform and base of the unit.
The water seal grooves between the base, and top of the unit, and between the top of the unit and the valve
cover must be filled with liquid.
The supply water temperature must be at least 42
o
F. (This may be an issue for rural or municipal water
supplies.)
If these factors are not met, supplemental heat is recommended. Please see Supplemental Heat in the Special
Situations section of this manual, page 5 for specific recommendations.
A.
Location
- Putting the fountain in a location that offers protection from the wind will enhance the
performance of the fountain. Livestock will tend to gather in this protected area, enticing them to drink more. If
possible, the side that supply line enters the fountain should be opposite of prevailing winter wind to give
additional protection to the supply line.
B.
Water Supply Line
-
The horizontal underground water line (#1) should be sized to account for pressure
drop, relating to distance, at least ¾” in diameter (1” recommended) and 1’ below normal frost depth. A 3/4” (1”
recommended) vertical supply pipe (#2) is recommended for Thrifty King units. A shut-off valve (#3) may be
installed under the fountain for easier servicing. For optimum serviceability a stop and waste valve can be
installed below frost level to drain water back when unit is not in use. Flush water supply line thoroughly before
connecting to fountain.