Trouble Shooting 

Problem 

Solution 

Water in Trough Too 

Warm  

Adjust thermostat to lower temperature 

Check to see if thermostat has failed by contacts burning closed 

Ice in Trough 

Check fuses or circuit breakers 

Check all heating elements to make sure they are working and hot 

Adjust thermostat to higher temperature 

Check for voltage from thermostat output 

Check voltage to fountain with and without electrical load 

Check that heaters are wired properly 

Valve Freezing 

Check that cable heater is installed properly and fastened to water supply line and is 

working when heaters are hot 

Check for missing or damaged insulation 

Check for air gaps for wind penetrations 

Supply line Freezing 

Check that the cable heater is uncoiled and fastened around valve, to supply line and 

is working when heaters are hot 

Check that supply piping is centered in riser tube 

Check that riser tube is free of water and mud that may freeze 

Check that flexible hose does not touch side of casing or frame 

Check casing for air leaks 

Check for air gaps between casing and concrete 

Valve won’t stop dripping 

Check float adjustment  and  for waterlogged float or float rubbing on side of valve 

compartment 

Check for excessive system water pressure 

Disassemble valve and check for sand or scale in valve rubber.  Also check valve 

orifice outlet for wear and damage.  A screen or filter may be required with sandy or 

scaly water 

Turn valve rubber over and re-assemble 

Low water flow 

Check that valve inlet is not plugged or supply hose is not kinked 

Check system pressure from supply hose by installing a tee and a pressure gauge 

directly in front of the valve to check pressure drop when valve is open.  A severe 

pressure drop indicates a restriction or undersized supply system. 

Check that shutoff valves are fully open 

Valve Rubber 

Use Thread Sealant 

OmniFount Large Series Instruction Manual

6

August 13, 2022

Содержание Fresh Water For Life OmniFount 5

Страница 1: ...ng fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Read and understand all instructions before insta...

Страница 2: ...a stop and waste valve can be installed below frost level to drain water when unit is not in use Vertical supply line must be centered in riser tube to provide an air space between the line and froze...

Страница 3: ...ze of your animals when determining the dimensions of your platform The concrete step and platform should slope away from the fountain for drainage A rough broom finish to concrete surface provides be...

Страница 4: ...cable heater to the water supply as far down the riser tube as possible with the cable twist ties provided This heater is water tight but should not be immersed in water Heater may cross over itself...

Страница 5: ...warmer than desired turn the thermostat down If there is ice forming on the surface of the water turn the thermostat up Only slight adjustments should be made to the thermostat at any time A 1 16 tur...

Страница 6: ...fter the water and debris has drained reinstall the plug and let the tank refill Now is a good time to readjust the float if needed Reinstall cover and you are done Ritchie Valves Ritchie valves come...

Страница 7: ...ed in riser tube Check that riser tube is free of water and mud that may freeze Check that flexible hose does not touch side of casing or frame Check casing for air leaks Check for air gaps between ca...

Страница 8: ...of a moisture resistant exterior grade outlet is recommended in these units Do not use extension cords CABLE HEATER 240V TROUGH HEATER 240V THERMOSTAT FENWAL OR DISC WARNING CHECK NAMEPLATE FOR CORRE...

Страница 9: ...pkg 20 18633 Plug 3 Water Channel 2 pkg 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 18074...

Страница 10: ...el 2 pkg 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS...

Страница 11: ...el 2 pkg 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS...

Страница 12: ...r to any product that is installed and or used contrary to Ritchie Industries installation instructions and instructions for use The limited warranty shall also not apply to any product whose exterior...

Страница 13: ...This page intentionally left blank OmniFount Large Series Instruction Manual 12 August 13 2022...

Страница 14: ...Part 18735 August 13 2022...

Отзывы: